Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Behaviour of stainless and high strength steel bolt assemblies at elevated temperatures—A review
This study documents important aspects of bolt assembly performance in structural steel
connections at elevated temperatures that have not been the subject of detailed …
connections at elevated temperatures that have not been the subject of detailed …
Performance of steel–concrete composite structures in fire
YC Wang - Progress in Structural Engineering and Materials, 2005 - Wiley Online Library
This paper presents a review of recent studies of the behaviour of steel–concrete composite
structures in fire, including an assessment of research investigations and their implications …
structures in fire, including an assessment of research investigations and their implications …
Fracture behavior of high-strength bolted steel connections at elevated temperatures
In fire events, to utilize catenary effect and accommodate large deformation in beams
demands a sufficient deformation capacity and ductility in steel bolted connections, which is …
demands a sufficient deformation capacity and ductility in steel bolted connections, which is …
Towards a consistent design approach for steel joints under generalized loading
LS Da Silva - Journal of Constructional Steel Research, 2008 - Elsevier
The behaviour of steel joints is complex and requires the proper consideration of a multitude
of phenomena, ranging from material non-linearity (plasticity, strain-hardening), non-linear …
of phenomena, ranging from material non-linearity (plasticity, strain-hardening), non-linear …
[PDF][PDF] Dimensionamento de elementos de concreto armado em situação de incêndio
CN Costa - São Paulo. Universidade de São Paulo, 2008 - teses.usp.br
RESUMO A maioria dos materiais estruturais de Construção Civil tem suas propriedades
mecânicas reduzidas, quando submetidos a temperaturas elevadas. Por isso, a capacidade …
mecânicas reduzidas, quando submetidos a temperaturas elevadas. Por isso, a capacidade …
[HTML][HTML] Low-velocity impact behavior of one-part engineered geopolymer composite under extreme temperatures
Y Zhou, Z Hu, X Sui, H Shi, Y Lin, J Pan… - Composites Part A …, 2025 - Elsevier
This study investigated the mechanical properties and impact resistance of one-part
engineered geopolymer composites (EGC), with a particular focus on the low-velocity impact …
engineered geopolymer composites (EGC), with a particular focus on the low-velocity impact …
Effects of partial fire protection on temperature developments in steel joints protected by intumescent coating
This paper presents experimental results of temperature distribution in fire in four typical
types of steel–concrete composite joint (web cleat, fin plate, flush endplate and flexible …
types of steel–concrete composite joint (web cleat, fin plate, flush endplate and flexible …
A numerical investigation into strip** failure of bolt assemblies at elevated temperatures
A detailed finite element (FE) study is presented investigating the factors affecting the failure
modes of high strength and stainless steel bolt assemblies under tensile force at ambient …
modes of high strength and stainless steel bolt assemblies under tensile force at ambient …
Temperatures during fire tests on structure and its prediction according to Eurocodes
F Wald, J Chlouba, A Uhlíř, P Kallerová, M Štujberová - Fire safety journal, 2009 - Elsevier
The paper reports on an experimental programme to investigate the global structural
behaviour of a compartment in the three-storey steel frame building in a plant of the Mittal …
behaviour of a compartment in the three-storey steel frame building in a plant of the Mittal …
Quantitative risk assessment methods of evacuation safety for collapse of large steel structure gymnasium caused by localized fire
G Zhang, G Zhu, G Yuan, Y Wang - Safety science, 2016 - Elsevier
A risk assessment method was proposed to evaluate the evacuation safety in the collapse of
a large steel-structured gymnasium caused by localized fire. The criterion for safety …
a large steel-structured gymnasium caused by localized fire. The criterion for safety …