Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
CT-based migration analysis is more precise than radiostereometric analysis for tibial implants: a phantom study on a porcine cadaver
LHW Engseth, A Schulz, AH Pripp… - Acta …, 2023 - pmc.ncbi.nlm.nih.gov
Background and purpose Radiostereometric analysis (RSA) is the gold standard for
migration analysis, but computed tomography analysis methods (CTRSA) have shown …
migration analysis, but computed tomography analysis methods (CTRSA) have shown …
Comparison between model-based RSA and an AI-based CT-RSA: an accuracy study of 30 patients
A Christensson, HM Nemati, G Flivik - Acta Orthopaedica, 2024 - pmc.ncbi.nlm.nih.gov
Background and purpose Radiostereometry (RSA) is the current gold standard for
evaluating early implant migration. CT-based migration analysis is a promising method, with …
evaluating early implant migration. CT-based migration analysis is a promising method, with …
Inducible displacement of cementless total knee arthroplasty components with conventional and weight‐bearing CT‐based radiostereometric analysis
RA Hext, BL Kaptein, JL Howard… - Journal of …, 2024 - Wiley Online Library
Aseptic loosening remains one of the top causes of revision surgery of total knee
arthroplasty (TKA). Radiostereometric analysis (RSA) is used in research to measure …
arthroplasty (TKA). Radiostereometric analysis (RSA) is used in research to measure …
Dose reduction does not impact the precision of CT-based RSA in tibial implants: a diagnostic accuracy study on precision in a porcine cadaver
Ø Frank-David, LHW Engseth, AH Pripp… - Acta …, 2023 - pmc.ncbi.nlm.nih.gov
Background and purpose Radiostereometric analysis (RSA) is the gold standard for
evaluation of migration of implants. CT-RSA has been shown to have precision at the level …
evaluation of migration of implants. CT-RSA has been shown to have precision at the level …
Accuracy and precision of Volumetric Matching Micromotion Analysis (V3MA) is similar to RSA for tibial component migration in TKA
NN de Laat, LA Koster, BC Stoel… - Journal of …, 2025 - Wiley Online Library
Radiostereometric analysis (RSA) is the current gold standard to determine implant
migration, but it requires bone markers and special equipment. Therefore, we developed …
migration, but it requires bone markers and special equipment. Therefore, we developed …
[HTML][HTML] Mobile-bearing total ankle replacement in vivo kinematic assessment: a prospective study protocol
Total ankle prosthesis as a surgical solution in the case of end-stage osteoarthritis has seen
a considerable increase in the last two decades. This study protocol arises from the need to …
a considerable increase in the last two decades. This study protocol arises from the need to …
Low dose CT-based spatial analysis (CTSA) to measure implant migration after ceramic hip resurfacing arthroplasty (HRA): A phantom study
SG Clarke, K Logishetty… - Proceedings of the …, 2023 - journals.sagepub.com
Implant migration is a predictor of arthroplasty survivorship. It is crucial to monitor the
migration of novel hip prostheses within premarket clinical investigations. RSA is the gold …
migration of novel hip prostheses within premarket clinical investigations. RSA is the gold …
CT-based radiostereometric analysis for assessing midfoot kinematics: precision compared with marker-based radiostereometry
Background and purpose 3-dimensional midfoot motion is hard to evaluate in clinical
practice. We present a new computed tomography (CT)-based radiostereometric analysis …
practice. We present a new computed tomography (CT)-based radiostereometric analysis …
Comparison of Marker‐Based RSA and CT‐RSA for Analyzing Micromotions After Distal Radius Osteotomy: A 1‐Year Retrospective Study of 24 Patients
Radiostereometric Analysis (RSA) is the most accurate method for determining early
micromotions of orthopedic implants. Computed Tomography Radiostereometric Analysis …
micromotions of orthopedic implants. Computed Tomography Radiostereometric Analysis …
[HTML][HTML] Comparison of the CT-based micromotion analysis method versus marker-based RSA in measuring femoral head translation and evaluation of its intra-and …
V Angelomenos, B Shareghi, R Itayem… - Acta …, 2025 - pmc.ncbi.nlm.nih.gov
Background and purpose Computed tomography radiostereometric analysis (CT-RSA)
assesses implant micromovements using low-dose CT scans. We aimed to investigate …
assesses implant micromovements using low-dose CT scans. We aimed to investigate …