Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …
Dosimetry of small static fields used in external photon beam radiotherapy: summary of TRS‐483, the IAEA–AAPM international Code of Practice for reference and …
Purpose A joint IAEA/AAPM international working group has developed a Code of Practice
(CoP) for the dosimetry of small static fields used in external megavoltage photon beam …
(CoP) for the dosimetry of small static fields used in external megavoltage photon beam …
Small fields: nonequilibrium radiation dosimetry
Advances in radiation treatment with beamlet‐based intensity modulation, image‐guided
radiation therapy, and stereotactic radiosurgery (including specialized equipments like …
radiation therapy, and stereotactic radiosurgery (including specialized equipments like …
Accelerator beam data commissioning equipment and procedures: report of the TG‐106 of the Therapy Physics Committee of the AAPM
IJ Das, CW Cheng, RJ Watts, A Ahnesjö… - Medical …, 2008 - Wiley Online Library
For commissioning a linear accelerator for clinical use, medical physicists are faced with
many challenges including the need for precision, a variety of testing methods, data …
many challenges including the need for precision, a variety of testing methods, data …
Dosimetry tools and techniques for IMRT
Intensity modulated radiation therapy (IMRT) poses a number of challenges for properly
measuring commissioning data and quality assurance (QA) radiation dose distributions. This …
measuring commissioning data and quality assurance (QA) radiation dose distributions. This …
Report of AAPM Task Group 155: megavoltage photon beam dosimetry in small fields and non‐equilibrium conditions
Small‐field dosimetry used in advance treatment technologies poses challenges due to loss
of lateral charged particle equilibrium (LCPE), occlusion of the primary photon source, and …
of lateral charged particle equilibrium (LCPE), occlusion of the primary photon source, and …
Current status and future perspective of flattening filter free photon beams
Purpose: Flattening filters (FFs) have been considered as an integral part of the treatment
head of a medical accelerator for more than 50 years. The reasons for the longstanding use …
head of a medical accelerator for more than 50 years. The reasons for the longstanding use …
Characterizing the influence of detector density on dosimeter response in non-equilibrium small photon fields
The impact of density and atomic composition on the dosimetric response of various
detectors in small photon radiation fields is characterized using a'density-correction'factor, F …
detectors in small photon radiation fields is characterized using a'density-correction'factor, F …
Measurement of output factors for small photon beams
OA Sauer, J Wilbert - Medical physics, 2007 - Wiley Online Library
A variety of detectors and procedures for the measurement of small field output factors are
discussed in the current literature. Different detectors with or without corrections are …
discussed in the current literature. Different detectors with or without corrections are …
Detector dose response in megavoltage small photon beams. I. Theoretical concepts
Purpose: To explain the reasons for significant quality correction factors in megavoltage
small photon fields and clarify the underlying concepts relevant to dosimetry under such …
small photon fields and clarify the underlying concepts relevant to dosimetry under such …