Short-T2 MRI: Principles and recent advances
Among current modalities of biomedical and diagnostic imaging, MRI stands out by virtue of
its versatile contrast obtained without ionizing radiation. However, in various cases, eg …
its versatile contrast obtained without ionizing radiation. However, in various cases, eg …
Spiral demystified
BMA Delattre, RM Heidemann, LA Crowe… - Magnetic resonance …, 2010 - Elsevier
Spiral acquisition schemes offer unique advantages such as flow compensation, efficient k-
space sampling and robustness against motion that make this option a viable choice among …
space sampling and robustness against motion that make this option a viable choice among …
Transmit sense
U Katscher, P Börnert, C Leussler… - … in Medicine: An …, 2003 - Wiley Online Library
The idea of using parallel imaging to shorten the acquisition time by the simultaneous use of
multiple receive coils can be adapted for the parallel transmission of a spatially‐selective …
multiple receive coils can be adapted for the parallel transmission of a spatially‐selective …
Sampling density compensation in MRI: rationale and an iterative numerical solution
JG Pipe, P Menon - … Resonance in Medicine: An Official Journal …, 1999 - Wiley Online Library
Data collection of MRI which is sampled nonuniformly in k‐space is often interpolated onto a
Cartesian grid for fast reconstruction. The collected data must be properly weighted before …
Cartesian grid for fast reconstruction. The collected data must be properly weighted before …
Resampling of data between arbitrary grids using convolution interpolation
For certain medical applications resampling of data is required. In magnetic resonance
tomography (MRT) or computer tomography (CT), eg, data may be sampled on …
tomography (MRT) or computer tomography (CT), eg, data may be sampled on …
Reduced aliasing artifacts using variable‐density k‐space sampling trajectories
CM Tsai, DG Nishimura - … in Medicine: An Official Journal of the …, 2000 - Wiley Online Library
A variable‐density k‐space sampling method is proposed to reduce aliasing artifacts in MR
images. Because most of the energy of an image is concentrated around the k‐space center …
images. Because most of the energy of an image is concentrated around the k‐space center …
Spiral phyllotaxis: the natural way to construct a 3D radial trajectory in MRI
D Piccini, A Littmann… - Magnetic resonance …, 2011 - Wiley Online Library
While radial 3D acquisition has been discussed in cardiac MRI for its excellent results with
radial undersampling, the self‐navigating properties of the trajectory need yet to be …
radial undersampling, the self‐navigating properties of the trajectory need yet to be …
Algebraic reconstruction of images from non-equidistant data
D Rosenfeld - US Patent 6,748,098, 2004 - Google Patents
The Fourier Transform (FT) is one of the most important Signal processing techniques in use
today. In particular, it finds a number of uses in medical imaging, including reconstruction of …
today. In particular, it finds a number of uses in medical imaging, including reconstruction of …
Acquisition‐weighted stack of spirals for fast high‐resolution three‐dimensional ultra‐short echo time MR imaging
Y Qian, FE Boada - … Resonance in Medicine: An Official Journal …, 2008 - Wiley Online Library
Ultra‐short echo time (UTE) MRI requires both short excitation (∼ 0.5 ms) and short
acquisition delay (< 0.2 ms) to minimize T2‐induced signal decay. These requirements …
acquisition delay (< 0.2 ms) to minimize T2‐induced signal decay. These requirements …
Non‐Cartesian data reconstruction using GRAPPA operator gridding (GROG)
N Seiberlich, FA Breuer, M Blaimer… - … in Medicine: An …, 2007 - Wiley Online Library
A novel approach that uses the concepts of parallel imaging to grid data sampled along a
non‐Cartesian trajectory using GRAPPA operator gridding (GROG) is described. GROG …
non‐Cartesian trajectory using GRAPPA operator gridding (GROG) is described. GROG …