Short-T2 MRI: Principles and recent advances

M Weiger, KP Pruessmann - Progress in nuclear magnetic resonance …, 2019 - Elsevier
Among current modalities of biomedical and diagnostic imaging, MRI stands out by virtue of
its versatile contrast obtained without ionizing radiation. However, in various cases, eg …

Spiral demystified

BMA Delattre, RM Heidemann, LA Crowe… - Magnetic resonance …, 2010 - Elsevier
Spiral acquisition schemes offer unique advantages such as flow compensation, efficient k-
space sampling and robustness against motion that make this option a viable choice among …

Transmit sense

U Katscher, P Börnert, C Leussler… - … in Medicine: An …, 2003 - Wiley Online Library
The idea of using parallel imaging to shorten the acquisition time by the simultaneous use of
multiple receive coils can be adapted for the parallel transmission of a spatially‐selective …

Sampling density compensation in MRI: rationale and an iterative numerical solution

JG Pipe, P Menon - … Resonance in Medicine: An Official Journal …, 1999 - Wiley Online Library
Data collection of MRI which is sampled nonuniformly in k‐space is often interpolated onto a
Cartesian grid for fast reconstruction. The collected data must be properly weighted before …

Resampling of data between arbitrary grids using convolution interpolation

V Rasche, R Proksa, R Sinkus… - IEEE transactions on …, 1999 - ieeexplore.ieee.org
For certain medical applications resampling of data is required. In magnetic resonance
tomography (MRT) or computer tomography (CT), eg, data may be sampled on …

Reduced aliasing artifacts using variable‐density k‐space sampling trajectories

CM Tsai, DG Nishimura - … in Medicine: An Official Journal of the …, 2000 - Wiley Online Library
A variable‐density k‐space sampling method is proposed to reduce aliasing artifacts in MR
images. Because most of the energy of an image is concentrated around the k‐space center …

Spiral phyllotaxis: the natural way to construct a 3D radial trajectory in MRI

D Piccini, A Littmann… - Magnetic resonance …, 2011 - Wiley Online Library
While radial 3D acquisition has been discussed in cardiac MRI for its excellent results with
radial undersampling, the self‐navigating properties of the trajectory need yet to be …

Algebraic reconstruction of images from non-equidistant data

D Rosenfeld - US Patent 6,748,098, 2004 - Google Patents
The Fourier Transform (FT) is one of the most important Signal processing techniques in use
today. In particular, it finds a number of uses in medical imaging, including reconstruction of …

Acquisition‐weighted stack of spirals for fast high‐resolution three‐dimensional ultra‐short echo time MR imaging

Y Qian, FE Boada - … Resonance in Medicine: An Official Journal …, 2008 - Wiley Online Library
Ultra‐short echo time (UTE) MRI requires both short excitation (∼ 0.5 ms) and short
acquisition delay (< 0.2 ms) to minimize T2‐induced signal decay. These requirements …

Non‐Cartesian data reconstruction using GRAPPA operator gridding (GROG)

N Seiberlich, FA Breuer, M Blaimer… - … in Medicine: An …, 2007 - Wiley Online Library
A novel approach that uses the concepts of parallel imaging to grid data sampled along a
non‐Cartesian trajectory using GRAPPA operator gridding (GROG) is described. GROG …