Nanoparticles for imaging: top or flop?
Nanoparticles are frequently suggested as diagnostic agents. However, except for iron oxide
nanoparticles, diagnostic nanoparticles have been barely incorporated into clinical use so …
nanoparticles, diagnostic nanoparticles have been barely incorporated into clinical use so …
Radioembolization of hepatic lesions from a radiobiology and dosimetric perspective
M Cremonesi, C Chiesa, L Strigari, M Ferrari… - Frontiers in …, 2014 - frontiersin.org
Radioembolization (RE) of liver cancer with 90Y-microspheres has been applied in the last
two decades with notable responses and acceptable toxicity. Two types of microspheres are …
two decades with notable responses and acceptable toxicity. Two types of microspheres are …
EANM dosimetry committee series on standard operational procedures: a unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization …
The aim of this standard operational procedure is to standardize the methodology employed
for the evaluation of pre-and post-treatment absorbed dose calculations in 90 Y microsphere …
for the evaluation of pre-and post-treatment absorbed dose calculations in 90 Y microsphere …
PennPET Explorer: human imaging on a whole-body imager
The PennPET Explorer, a prototype whole-body imager currently operating with a 64-cm
axial field of view, can image the major body organs simultaneously with higher sensitivity …
axial field of view, can image the major body organs simultaneously with higher sensitivity …
Total body PET: why, how, what for?
PET instruments are now available with a long axial field-of-view (LAFOV) to enable imaging
the total-body, or at least head and torso, simultaneously and without bed translation. This …
the total-body, or at least head and torso, simultaneously and without bed translation. This …
Quantitative comparison of PET and Bremsstrahlung SPECT for imaging the in vivo yttrium-90 microsphere distribution after liver radioembolization
Background After yttrium-90 (90Y) microsphere radioembolization (RE), evaluation of
extrahepatic activity and liver dosimetry is typically performed on 90Y Bremsstrahlung …
extrahepatic activity and liver dosimetry is typically performed on 90Y Bremsstrahlung …
A guide to 90Y radioembolization and its dosimetry
Radioembolization gains continuous traction as a primarily palliative radiation treatment for
hepatic tumours. A form of nuclear medicine therapy, Yttrium-90 containing microspheres …
hepatic tumours. A form of nuclear medicine therapy, Yttrium-90 containing microspheres …
Post-radioembolization yttrium-90 PET/CT-part 2: dose-response and tumor predictive dosimetry for resin microspheres
YH Kao, JD Steinberg, YS Tay, GKY Lim, J Yan… - EJNMMI research, 2013 - Springer
Background Coincidence imaging of low-abundance yttrium-90 (90 Y) internal pair
production by positron emission tomography with integrated computed tomography …
production by positron emission tomography with integrated computed tomography …
A multicentre comparison of quantitative 90Y PET/CT for dosimetric purposes after radioembolization with resin microspheres: The QUEST Phantom Study
KP Willowson, M Tapner… - European journal of …, 2015 - Springer
Purpose To investigate and compare the quantitative accuracy of 90 Y imaging across
different generation PET/CT scanners, for the purpose of dosimetry after radioembolization …
different generation PET/CT scanners, for the purpose of dosimetry after radioembolization …
[HTML][HTML] Quantitative imaging for targeted radionuclide therapy dosimetry-technical review
Targeted radionuclide therapy (TRT) is a promising technique for cancer therapy. However,
in order to deliver the required dose to the tumor, minimize potential toxicity in normal …
in order to deliver the required dose to the tumor, minimize potential toxicity in normal …