Effect of forward head posture on thoracic shape and respiratory function

T Koseki, F Kakizaki, S Hayashi, N Nishida… - Journal of physical …, 2019 - jstage.jst.go.jp
[Purpose] This study investigated the effect of forward head posture on upper and lower
thoracic shape in adults to better understand the relationship between a forward head …

Scaling of musculoskeletal models from static and dynamic trials

ME Lund, MS Andersen, M de Zee… - International …, 2015 - Taylor & Francis
Subject-specific scaling of cadaver-based musculoskeletal models is important for accurate
musculoskeletal analysis within multiple areas such as ergonomics, orthopaedics and …

Standardization proposal of soft tissue artefact description for data sharing in human motion measurements

A Cereatti, T Bonci, M Akbarshahi, K Aminian… - Journal of …, 2017 - Elsevier
Soft tissue artefact (STA) represents one of the main obstacles for obtaining accurate and
reliable skeletal kinematics from motion capture. Many studies have addressed this issue …

[HTML][HTML] Effect of the soft tissue artifact on marker measurements and on the calculation of the helical axis of the knee during a gait cycle: A study on the CAMS-Knee …

A Ancillao, E Aertbeliën, J De Schutter - Human Movement Science, 2021 - Elsevier
The soft tissue artifact (STA) is a phenomenon occurring when the motion of bones or
anatomical segments is measured by means of skin markers: the biological tissues between …

Refining muscle geometry and wrap** in the TLEM 2 model for improved hip contact force prediction

E De Pieri, ME Lund, A Gopalakrishnan… - PloS one, 2018 - journals.plos.org
Musculoskeletal models represent a powerful tool to gain knowledge on the internal forces
acting at the joint level in a non-invasive way. However, these models can present some …

Surface marker cluster translation, rotation, scaling and deformation: Their contribution to soft tissue artefact and impact on knee joint kinematics

DL Benoit, M Damsgaard, MS Andersen - Journal of biomechanics, 2015 - Elsevier
When recording human movement with stereophotogrammetry, skin deformation and
displacement (soft tissue artefact; STA) inhibits surface markers' ability to validly represent …

On the accuracy of the Conventional gait Model: Distinction between marker misplacement and soft tissue artefact errors

F Leboeuf, A Barre, K Aminian, M Sangeux - Journal of Biomechanics, 2023 - Elsevier
There is a lack of knowledge about the accuracy of the Conventional Gait Model (CGM),
compared to the true bone motion. Accuracy is hindered by both marker misplacement and …

Soft tissue artifact assessment during treadmill walking in subjects with total knee arthroplasty

A Barré, JP Thiran, BM Jolles… - IEEE transactions on …, 2013 - ieeexplore.ieee.org
Accurate measurement of knee kinematics during functional activities suffers mainly from
soft tissue artifact (STA): the combination of local surface deformations and rigid movement …

Soft tissue displacement over pelvic anatomical landmarks during 3-D hip movements

V Camomilla, T Bonci, A Cappozzo - Journal of Biomechanics, 2017 - Elsevier
The position, in a pelvis-embedded anatomical coordinate system, of skin points located
over the following anatomical landmarks (AL) was determined while the hip assumed …

IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement—A proof of concept

M Zabat, A Ababou, N Ababou, R Dumas - Medical & biological …, 2019 - Springer
A lot of attention has been paid to wearable inertial sensors regarded as an alternative
solution for outdoor human motion tracking. Relevant joint angles can only be calculated …