Biodegradable bone implants in orthopedic applications: a review
A biologically-validated biodegradable material must comfortably stay in the physiological
environment it is placed in, before finally disappearing over the intended period of time with …
environment it is placed in, before finally disappearing over the intended period of time with …
Biomechanics of spinal implants—a review
Spinal instrumentations have been classified as rigid fixation, total disc replacement and
dynamic stabilization system for treatment of various spinal disorders. The efficacy and …
dynamic stabilization system for treatment of various spinal disorders. The efficacy and …
Finite element and experimental analysis to select patient's bone condition specific porous dental implant, fabricated using additive manufacturing
Background Differences in patients' bone conditions lead to variations in the bio-mechanical
environment at the peri-implant bone after implantation. It is therefore imperative to design …
environment at the peri-implant bone after implantation. It is therefore imperative to design …
Expandable pedicle screw may have better fixation than normal pedicle screw: preclinical investigation on instrumented L4-L5 vertebrae based on various …
Lumbar spine fracture is typically treated by means of screw fixation, the primary aim of
which is to reduce fracture by achieving bony union such that the spinal anatomy is restored …
which is to reduce fracture by achieving bony union such that the spinal anatomy is restored …
Effect of pedicle screw angles on the fracture risk of the human vertebra: A patient-specific computational model
The assessment of a human vertebra's stability after a screws fixation procedure and its
fracture risk is still an open clinical problem. The accurate evaluation of fracture risk requires …
fracture risk is still an open clinical problem. The accurate evaluation of fracture risk requires …
A biomechanics-aware robot-assisted steerable drilling framework for minimally invasive spinal fixation procedures
In this paper, we propose a novel biomechanics-aware robot-assisted steerable drilling
framework with the goal of addressing common complications of spinal fixation procedures …
framework with the goal of addressing common complications of spinal fixation procedures …
Patient-specific finite element models of posterior pedicle screw fixation: effect of screw's size and geometry
M Sensale, T Vendeuvre, C Schilling… - … in Bioengineering and …, 2021 - frontiersin.org
Pedicle screw fixation is extensively performed to treat spine injuries or diseases and it is
common for thoracolumbar fractures. Post-operative complications may arise from this …
common for thoracolumbar fractures. Post-operative complications may arise from this …
Design of patient specific basal dental implant using Finite Element method and Artificial Neural Network technique
The bone conditions of mandibular bone vary from patient to patient, and as a result, a
patient-specific dental implant needs to be designed. The basal dental implant is implanted …
patient-specific dental implant needs to be designed. The basal dental implant is implanted …
Design of patient specific bone stiffness mimicking scaffold
The difference in stiffness of a patient's bone and bone implant causes stress shielding.
Thus, implants which match the stiffness of bone of the patient result in better bone growth …
Thus, implants which match the stiffness of bone of the patient result in better bone growth …
Design and manufacturing of biomimetic porous metal implants
The stress-shielding effect can be minimized by using porous materials with pre-determined
implant stiffness. This study aims to design interconnected porous metal implants that …
implant stiffness. This study aims to design interconnected porous metal implants that …