Power system stability with a high penetration of inverter-based resources

Y Gu, TC Green - Proceedings of the IEEE, 2022 - ieeexplore.ieee.org
Inverter-based resources (IBRs) possess dynamics that are significantly different from those
of synchronous-generator-based sources and as IBR penetrations grow the dynamics of …

Harmonic stability in power electronic-based power systems: Concept, modeling, and analysis

X Wang, F Blaabjerg - IEEE Transactions on Smart Grid, 2018 - ieeexplore.ieee.org
The large-scale integration of power electronic based systems poses new challenges to the
stability and power quality of modern power grids. The wide timescale and frequency …

Sideband harmonic instability of paralleled inverters with asynchronous carriers

D Yang, X Wang, F Blaabjerg - IEEE Transactions on Power …, 2017 - ieeexplore.ieee.org
Paralleled inverters with asynchronous carriers are increasingly emerging into renewable
power plants and other power-electronic-based power systems. The sideband harmonics …

A fully parallel architecture for designing frequency-agile and real-time reconfigurable FPGA-based RF digital transmitters

DC Dinis, RF Cordeiro, ASR Oliveira… - IEEE Transactions …, 2017 - ieeexplore.ieee.org
Real-time frequency agility is one of the key limitations of current all-digital transmitters
(ADTs). In this paper, to address this problem, an ADT based on direct-RF generation is …

A multi-frequency input-admittance model of locomotive rectifier considering PWM sideband harmonic coupling in electrical railways

X Meng, Z Liu, G Li, X Chen, S Wu… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Electrical railway harmonic instability issues are common in the high-frequency range. The
effective frequency of the traditional converter's small-signal averaging model is below 1/2 …

A TDD distributed MIMO testbed using a 1-bit radio-over-fiber fronthaul architecture

L Aabel, S Jacobsson, M Coldrey… - IEEE Transactions …, 2024 - ieeexplore.ieee.org
We present the uplink and downlink of a time-division duplex distributed multiple-input
multiple-output (D-MIMO) testbed, based on a 1-bit radio-over-fiber architecture, which is low …

Stable and passive high-power dual active bridge converters interfacing MVDC grids

FD Freijedo, E Rodriguez-Diaz… - IEEE Transactions on …, 2018 - ieeexplore.ieee.org
Dual active bridge (DAB) is a topology that is receiving more and more attention as a
potential solution to interface dc grids of different voltage levels. From a system level, the …

Harmonic quantitative analysis for dead-time effects in SPWM inverters

N Jiao, S Wang, T Liu, Y Wang, Z Chen - IEEE Access, 2019 - ieeexplore.ieee.org
Dead-time is commonly designed to avoid shoot-through phenomenon within each arm in
voltage source converter. The presence of dead-time tends to cause a power quality issue …

Multivariable high-frequency input-admittance of grid-connected converters: Modeling, validation, and implications on stability

FD Freijedo, M Ferrer, D Dujic - IEEE Transactions on Industrial …, 2019 - ieeexplore.ieee.org
Modern grids are facing a massive integration of power electronics devices, usually
associated to instability issues. In order to assess the likelihood and severity of harmonic …

Multi-Frequency Small-Signal Model for Single-Phase Grid-Tied Inverters Considering the Effect of PWM

Y Jiang, Y Sun, J Lin, S **e, M Su - IEEE Transactions on Power …, 2023 - ieeexplore.ieee.org
Recent studies have shown that harmonic instability may occur at frequencies above the
Nyquist frequency. To study this issue, the sidebands originating from modulation must be …