Influence of alloy components on arc erosion morphology of Ag/MeO electrical contact materials

C Wu, D Yi, W Wei, S Li, J Zhou - … of Nonferrous Metals Society of China, 2016 - Elsevier
Arc erosion morphologies of Ag/MeO (10) electrical contact materials after 50000 operations
under direct current of 19 V and 20 A and resistive load conditions were investigated using …

High current AC break arc contact erosion

JJ Shea - 2008 Proceedings of the 54th IEEE Holm Conference …, 2008 - ieeexplore.ieee.org
Contact break arc erosion fundamentals applicable to high power switching devices in air
(eg air-magnetic circuit breakers and contactors) are reviewed along with recent results …

Effects of metal fluoride/sulfide microparticles generated by consecutive high-pulse-power breakdowns on the insulating performance in compressed SF6

W Yan, Z Wang, W Shang, J Su, Z Cao… - Journal of Physics D …, 2020 - iopscience.iop.org
Spark gas switches (SGS) are widely used in various pulsed power applications where
sulfur hexafluoride (SF 6) is still dominant because of its excellent insulating performance …

[PDF][PDF] 滑动电接触磨损过程变化的实验研究

郭凤仪, 任志玲, 马同立, 赵汝彬, 陈忠华… - 电工技术 …, 2010 - dgjsxb.ces-transaction.com
摘要以浸铜碳滑板, 铜锡导线为摩擦副进行对磨实验, 得出摩擦系数湍流状波动曲线,
从而提出了滑板受流磨损过程的两个阶段: 跑合期, 相对稳定期. 针对滑板在跑合期磨耗量大的 …

[PDF][PDF] Contacts erosion modelling using ansys computer software and experimental research

P Borkowski, A Sienicki - Archives of Metallurgy and Materials, 2015 - yadda.icm.edu.pl
The paper presents a method of contacts' erosion modelling by using computer simulation
and analyzing heating, melting and evaporation processes, which cause contact erosion …

[PDF][PDF] Physical and Electrical Properties of Silver-Matrix Composites Reinforced with Various Forms of Refractory Phases

K Frydman, P Borkowski, K Pietrzak… - Archives of Metallurgy …, 2018 - journals.pan.pl
This paper presents technological trials aimed at producing Ag-W, Ag-WC, Ag-WC and Ag-
WC-C composite contact materials and characterizing their properties. These materials were …

Modelowanie i badanie erozji styków

P Borkowski - Zeszyty Naukowe. Rozprawy Naukowe/Politechnika …, 2008 - infona.pl
W pracy przedstawiono analizę i syntezę dotychczasowej wiedzy dotyczącej erozji styków
współczesnych łączników energoelektrycznych niskiego napięcia w szerokim zakresie …

[PDF][PDF] A mathematical model for calculating contact mass loss resulting from bridge disintegration in vacuum

P Borkowski - Archives of Electrical Engineering, 2011 - yadda.icm.edu.pl
The paper presents descriptions of bridge disintegration types and contact mass loss in the
bridge stage. There is presented Matlab solvers to solve equation describing dynamic …

[CITATION][C] 空气电弧对电极的烧蚀研究综述

吴艺红, 侯国斌, 邓晓峰, **兴文 - 电器与能效管理技术, 2017

[CITATION][C] 合金元素对 Ag/MeO 电接触材料电弧侵蚀形貌的影 (英文)

吴春萍, 易丹青, 翁桅, **素华, 周孑民 - **有色金属学报: 英文版, 2016