[HTML][HTML] Enhancing the fire-resistant performance of concrete-filled steel tube columns with steel fiber-reinforced concrete
Due to their excellent mechanical features, concrete-filled steel tube (CFST) columns are
usually employed in high-rise constructions; it is also significant to consider fire safety while …
usually employed in high-rise constructions; it is also significant to consider fire safety while …
[HTML][HTML] Structural behavior of reinforced concrete one-way slabs voided by polystyrene balls
In the last two decades, the use of voided (bubbled) slabs in constructions has been
increased because of several advantages such as light self-weight, cost-saving, and …
increased because of several advantages such as light self-weight, cost-saving, and …
[HTML][HTML] Flexural behavior of laced reinforced concrete moderately deep beams
This paper aims to experimentally and numerically investigate the flexural behavior of laced
reinforced concrete moderately deep beams. The study focuses on the influence of the …
reinforced concrete moderately deep beams. The study focuses on the influence of the …
[HTML][HTML] Conventional and bubbled slab strips under limited repeated loads: A comparative experimental study
This work primarily aimed to compare the bubble slabs experimentally with solid slabs under
the influence of limited repeated four-point loads. Therefore six slab strips were …
the influence of limited repeated four-point loads. Therefore six slab strips were …
Quasi-static analysis of biaxial voided slabs with openings
In this paper, 3D nonlinear finite element analyses (FEA) were conducted using the
ABAQUS program to investigate the openings' influences on voided slabs' structural …
ABAQUS program to investigate the openings' influences on voided slabs' structural …
[HTML][HTML] Retrofitting of reinforced concrete flat slabs with cut-out edge opening
In existing buildings, it is common to create openings in slabs due to service supplies. In this
case, the mechanical properties of slabs remarkably reduce, and strengthening must be …
case, the mechanical properties of slabs remarkably reduce, and strengthening must be …
Mechanical characteristics of deep beams considering variable a/d ratios: an experimental investigation
In this investigation, the influence of the shear span to the effective depth ratio on the
mechanical properties of deep beams was expansively illustrated. For this aim, three …
mechanical properties of deep beams was expansively illustrated. For this aim, three …
[HTML][HTML] Openings effects on the structural behavior of interior voided slab-column connections: An experimental study
This paper studied the openings' influences on the structural responses of interior voided
slab-column connections. Seven specimens were constructed with square slabs measuring …
slab-column connections. Seven specimens were constructed with square slabs measuring …
Finite element simulation of vertical temperature gradients in a standard W40× 235 steel beam
A finite element analysis was conducted in this research to understand the distribution of
temperatures along with the depth of the standard steel W40× 235 beam. The considered …
temperatures along with the depth of the standard steel W40× 235 beam. The considered …
Experimental study on axial compression for composite hollow column of steel fiber, high-strength lightweight aggregate concrete and angle steel
Z **ang, D Qiao, J Niu, W Liu - Scientific Reports, 2022 - nature.com
In order to study the axial compression performance for composite hollow column of steel
fiber, high-strength lightweight aggregate concrete and angle steel, the axial compression …
fiber, high-strength lightweight aggregate concrete and angle steel, the axial compression …