Reinforced concrete structures: A review of corrosion mechanisms and advances in electrical methods for corrosion monitoring
R Rodrigues, S Gaboreau, J Gance, I Ignatiadis… - … and Building Materials, 2021 - Elsevier
Steel corrosion is the main cause of deterioration of reinforced concrete (RC) structures. We
provide an up-to-date review on corrosion mechanisms and recent advances in electrical …
provide an up-to-date review on corrosion mechanisms and recent advances in electrical …
Electrical resistivity of concrete for durability evaluation: a review
Degradation processes in reinforced concrete structures that affect durability are partially
controlled by transport of aggressive ions through the concrete microstructure. Ions are …
controlled by transport of aggressive ions through the concrete microstructure. Ions are …
Non-destructive evaluation for corrosion monitoring in concrete: A review and capability of acoustic emission technique
Corrosion of reinforced concrete (RC) structures has been one of the major causes of
structural failure. Early detection of the corrosion process could help limit the location and …
structural failure. Early detection of the corrosion process could help limit the location and …
[HTML][HTML] Mechanical strength and durability analysis of mortars prepared with fly ash and nano-metakaolin
Pozzolans such as fly ash (FA) and nano-metakaolin (MK) are the two industrial wastes that
have attracted the attention of researchers due to their pozzolanic action that improves the …
have attracted the attention of researchers due to their pozzolanic action that improves the …
The effect of heat-curing on transport properties of low-calcium fly ash-based geopolymer concrete
A Noushini, A Castel - Construction and Building Materials, 2016 - Elsevier
The aim of this study is to evaluate the transport properties of class F fly ash-based
geopolymer concrete cured at various conditions. Twelve different heat curing regimes …
geopolymer concrete cured at various conditions. Twelve different heat curing regimes …
Electrical resistivity and electrical impedance measurement in mortar and concrete elements: A systematic review
Featured Application Systematic review of electrical resistivity and impedance
measurements methods and applications on cement-based materials. Abstract This paper …
measurements methods and applications on cement-based materials. Abstract This paper …
Electrical resistivity measurements for nondestructive evaluation of chloride-induced deterioration of reinforced concrete—A review
KPV Robles, JJ Yee, SH Kee - Materials, 2022 - mdpi.com
The objective of this study is to review, evaluate, and compare the existing research and
practices on electrical resistivity as a nondestructive technique in evaluating chloride …
practices on electrical resistivity as a nondestructive technique in evaluating chloride …
Corrosion damage detection in reinforced concrete using Rayleigh wave-based method
Corrosion of reinforcing bars is a dominant cause of degradation of reinforced concrete (RC)
structures. Over time, expansive products of corrosion build up tensile stresses within the …
structures. Over time, expansive products of corrosion build up tensile stresses within the …
Non-destructive and semi-destructive diagnostics of concrete structures in assessment of their durability
J Hoła, J Bień, K Schabowicz - Bulletin of the Polish Academy of …, 2015 - infona.pl
This paper proposes a comprehensive classification of test methods for the diagnosis of
concrete structures. The main focus is on the ranges of suitability of the particular methods …
concrete structures. The main focus is on the ranges of suitability of the particular methods …
Electrochemical sensors for monitoring the corrosion conditions of reinforced concrete structures: A review
RB Figueira - Applied Sciences, 2017 - mdpi.com
Several methods for corrosion monitoring of reinforced concrete structures (RCS) have been
proposed in the last few decades. These systems may be used either in new, existing or …