ICRU REPORT 97: MRI-guided radiation therapy using MRI-linear accelerators
The International Commission on Radiation Units and Measurements (ICRU), since its
inception in 1925, has had as its principal objective the development of internationally …
inception in 1925, has had as its principal objective the development of internationally …
Fibre-optic dosimetry for MRI-LINACs: a mini-review
For the past few decades, fibre-optic dosimeters (FODs) have been a focus of research for
dosimetry with LINACs, owing to a unique set of advantageous qualities: compact dosimeter …
dosimetry with LINACs, owing to a unique set of advantageous qualities: compact dosimeter …
Effects on skin dose from unwanted air gaps under bolus in an MR-guided linear accelerator (MR-linac) system
Bolus is commonly used in MV photon radiotherapy to increase superficial dose and
improve dose uniformity for treating shallow lesions. However, irregular patient body …
improve dose uniformity for treating shallow lesions. However, irregular patient body …
[HTML][HTML] Compact and Real-Time Radiation Dosimeter Using Silicon Photomultipliers for In Vivo Dosimetry in Radiation Therapy
J Kim, J Park, B Park, Y Kim, B Park, SH Park - Sensors, 2025 - mdpi.com
Existing dosimeters for radiation therapy are typically large, and their performance in in vivo
system applications has not been assessed. This study develops a compact real-time …
system applications has not been assessed. This study develops a compact real-time …
Non-contact scintillator imaging dosimetry for total body irradiation in radiotherapy
AP Niver, CG Hammer, WS Culberson… - Physics in Medicine …, 2024 - iopscience.iop.org
Objective. The goal of this work was to assess the potential use of non-contact scintillator
imaging dosimetry for tracking delivery in total body irradiation (TBI). Approach. Studies …
imaging dosimetry for tracking delivery in total body irradiation (TBI). Approach. Studies …
High-resolution entry and exit surface dosimetry in a 1.5 T MR-linac
The magnetic field of a transverse MR-linac alters electron trajectories as the photon beam
transits through materials, causing lower doses at flat entry surfaces and increased doses at …
transits through materials, causing lower doses at flat entry surfaces and increased doses at …
Radiation exposure in cone beam CT measured using a MOSFET and RPLGD dosimeter and Monte Carlo simulation in phantom
DC Kweon - Journal of X-Ray Science and Technology, 2023 - content.iospress.com
BACKGROUND: Due to the wide application of the cone beam computed tomography
(CBCT) in clinical practice, it is important to assess radiation dose of CBCT more accurately …
(CBCT) in clinical practice, it is important to assess radiation dose of CBCT more accurately …
Dosimetric properties of a prototype high field parallel MRI-Linac
J Begg - 2023 - unsworks.unsw.edu.au
Magnetic resonance imaging (MRI) linear accelerators (linacs) are a new treatment modality
combining the imaging of MRI and the therapy of linacs. The Australian MRI-linac is a 1 T …
combining the imaging of MRI and the therapy of linacs. The Australian MRI-linac is a 1 T …
[CITATION][C] Optical dosimeters for Radiotherapy with MRI-LINACs
LJ Madden - 2022