Are short-stem prostheses superior to conventional stem prostheses in primary total hip arthroplasty? A systematic review and meta-analysis of randomised controlled …

HD Liang, WY Yang, JK Pan, HT Huang, MH Luo… - BMJ open, 2018 - bmjopen.bmj.com
Objective Cementless total hip arthroplasty (THA) is associated with reliable clinical results
and high patient satisfaction. Short-stem prostheses (SS) were designed to achieve superior …

Wear of highly crosslinked polyethylene acetabular components: a review of RSA studies

SA Callary, LB Solomon, OT Holubowycz… - Acta …, 2015 - Taylor & Francis
Background and purpose—Wear rates of highly crosslinked polyethylene (XLPE) acetabular
components have varied considerably between different published studies. This variation is …

Two-to 9-year clinical results of alumina ceramic-on-ceramic THA

SB Murphy, TM Ecker, M Tannast - Clinical Orthopaedics and …, 2006 - journals.lww.com
Abstract From June 1997 to June 2003 we performed 194 total hip arthroplasties on 173
patients using alumina ceramic-on-ceramic bearings as part of a prospective United States …

Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density: a 2-year RSA and 8-year …

S Finnilä, N Moritz, E SvedströM, JJ Alm… - Acta …, 2016 - Taylor & Francis
Background and purpose—Low bone mineral density (BMD) may jeopardize the initial
component stability and delay osseointegration of uncemented acetabular cups in total hip …

Comparison of ceramic-on-ceramic to metal-on-polyethylene bearing surfaces in total hip arthroplasty: a meta-analysis of randomized controlled trials

D Hu, K Tie, X Yang, Y Tan, M Alaidaros… - Journal of orthopaedic …, 2015 - Springer
Background In recent years, the choice of ceramic-on-ceramic (COC) and metal-on-
polyethylene (MOP) in primary total hip arthroplasty (THA) remains controversial. The …

Migration patterns of acetabular cups: a systematic review and meta-analysis of RSA studies

CH Cho, BG Pijls, JM Abrahams, A Roerink… - Acta …, 2023 - pmc.ncbi.nlm.nih.gov
Background and purpose We conducted a systematic review and meta-analysis of RSA
studies to investigate the early and long-term migration patterns of acetabular cups and the …

[HTML][HTML] Total hip replacement and surface replacement for the treatment of pain and disability resulting from end-stage arthritis of the hip (review of technology …

A Clarke, R Pulikottil-Jacob, A Grove… - Health technology …, 2015 - pmc.ncbi.nlm.nih.gov
BACKGROUND Total hip replacement (THR) involves the replacement of a damaged hip
joint with an artificial hip prosthesis. Resurfacing arthroplasty (RS) involves replacement of …

Risk factors for liner wear and head migration in total hip arthroplasty: a systematic review

F Migliorini, N Maffulli, M Pilone, A Bell, F Hildebrand… - Scientific reports, 2023 - nature.com
Total hip arthroplasty (THA) is a successful orthopaedic surgical procedure, and its longevity
depends on bearing components and implant fixation. Optimizing polyethylene and …

Very low wear of non-remelted highly cross-linked polyethylene cups: an RSA study lasting up to 6 years

SM Röhrl, MG Li, KG Nilsson, B Nivbrant - Acta orthopaedica, 2007 - Taylor & Francis
Background and purpose Highly cross-linked polyethylenes (PEs) all appear to reduce wear
dramatically in laboratory studies, although there is substantial variation in this respect …

Exchange of modular components improves success of debridement, antibiotics, and implant retention: an observational study of 575 patients with infection after …

K Svensson, O Rolfson, E Nauclér, S Lazarinis… - JBJS Open …, 2020 - journals.lww.com
Background: Debridement, antibiotics, and implant retention (DAIR) is a surgical treatment
for periprosthetic joint infection (PJI). DAIR is a desirable treatment option from an economic …