A review on computer aided diagnosis of acute brain stroke
Amongst the most common causes of death globally, stroke is one of top three affecting over
100 million people worldwide annually. There are two classes of stroke, namely ischemic …
100 million people worldwide annually. There are two classes of stroke, namely ischemic …
[HTML][HTML] A review of the metrics used to assess auto-contouring systems in radiotherapy
Auto-contouring could revolutionise future planning of radiotherapy treatment. The lack of
consensus on how to assess and validate auto-contouring systems currently limits clinical …
consensus on how to assess and validate auto-contouring systems currently limits clinical …
Multi-organ segmentation of abdominal structures from non-contrast and contrast enhanced CT images
C Yu, CP Anakwenze, Y Zhao, RM Martin, EB Ludmir… - Scientific reports, 2022 - nature.com
Manually delineating upper abdominal organs at risk (OARs) is a time-consuming task. To
develop a deep-learning-based tool for accurate and robust auto-segmentation of these …
develop a deep-learning-based tool for accurate and robust auto-segmentation of these …
Fully-automated, CT-only GTV contouring for palliative head and neck radiotherapy
Planning for palliative radiotherapy is performed without the advantage of MR or PET
imaging in many clinics. Here, we investigated CT-only GTV delineation for palliative …
imaging in many clinics. Here, we investigated CT-only GTV delineation for palliative …
Addressing the global expertise gap in radiation oncology: the radiation planning assistant
PURPOSE Automation, including the use of artificial intelligence, has been identified as a
possible opportunity to help reduce the gap in access and quality for radiotherapy and other …
possible opportunity to help reduce the gap in access and quality for radiotherapy and other …
Comparing fully automated AI body composition measures derived from thin and thick slice CT image data
MH Lee, D Liu, JW Garrett, A Perez, R Zea… - Abdominal …, 2024 - Springer
Purpose To compare fully automated artificial intelligence body composition measures
derived from thin (1.25 mm) and thick (5 mm) slice abdominal CT data. Methods In this …
derived from thin (1.25 mm) and thick (5 mm) slice abdominal CT data. Methods In this …
Survey of methods and principles in three-dimensional reconstruction from two-dimensional medical images
M Sarmah, A Neelima, HR Singh - Visual computing for industry …, 2023 - Springer
Abstract Three-dimensional (3D) reconstruction of human organs has gained attention in
recent years due to advances in the Internet and graphics processing units. In the coming …
recent years due to advances in the Internet and graphics processing units. In the coming …
[HTML][HTML] An automated treatment planning framework for spinal radiation therapy and vertebral-level second check
Purpose Complicating factors such as time pressures, anatomic variants in the spine, and
similarities in adjacent vertebrae are associated with incorrect level treatments of the spine …
similarities in adjacent vertebrae are associated with incorrect level treatments of the spine …
[HTML][HTML] Multicenter comparison of measures for quantitative evaluation of contouring in radiotherapy
Background and Purpose A wide range of quantitative measures are available to facilitate
clinical implementation of auto-contouring software, on-going Quality Assurance (QA) and …
clinical implementation of auto-contouring software, on-going Quality Assurance (QA) and …
[HTML][HTML] Auto-contouring of cardiac substructures for Stereotactic arrhythmia radioablation (STAR): A STOPSTORM. eu consortium study
LHG van der Pol, O Blanck, M Grehn, T Blazek… - Radiotherapy and …, 2025 - Elsevier
Abstract Background/Purpose High doses to healthy cardiac substructures (CS) in
stereotactic arrhythmia radioablation (STAR) raise concerns regarding potential treatment …
stereotactic arrhythmia radioablation (STAR) raise concerns regarding potential treatment …