Magnetic resonance thermometry: Methodology, pitfalls and practical solutions
L Winter, E Oberacker, K Paul, Y Ji… - International Journal …, 2016 - Taylor & Francis
Clinically established thermal therapies such as thermoablative approaches or adjuvant
hyperthermia treatment rely on accurate thermal dose information for the evaluation and …
hyperthermia treatment rely on accurate thermal dose information for the evaluation and …
7‐T MR—from research to clinical applications?
Over 20 000 MR systems are currently installed worldwide and, although the majority
operate at magnetic fields of 1.5 T and below (ie about 70%), experience with 3‐T (in high …
operate at magnetic fields of 1.5 T and below (ie about 70%), experience with 3‐T (in high …
Magnetic resonance imaging at ultrahigh fields
K Uğurbil - IEEE transactions on biomedical engineering, 2014 - ieeexplore.ieee.org
Since the introduction of 4 T human systems in three academic laboratories circa 1990,
rapid progress in imaging and spectroscopy studies in humans at 4 T and animal model …
rapid progress in imaging and spectroscopy studies in humans at 4 T and animal model …
16‐channel bow tie antenna transceiver array for cardiac MR at 7.0 tesla
C Oezerdem, L Winter, A Graessl, K Paul… - Magnetic resonance …, 2016 - Wiley Online Library
Purpose To design, evaluate, and apply a bow tie antenna transceiver radiofrequency (RF)
coil array tailored for cardiac MRI at 7.0 Tesla (T). Methods The radiofrequency (RF) coil …
coil array tailored for cardiac MRI at 7.0 Tesla (T). Methods The radiofrequency (RF) coil …
[HTML][HTML] Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla
T Frauenrath, F Hezel, W Renz… - Journal of …, 2010 - Elsevier
Background To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging
of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram …
of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram …
Two‐dimensional sixteen channel transmit/receive coil array for cardiac MRI at 7.0 T: design, evaluation, and application
C Thalhammer, W Renz, L Winter… - Journal of Magnetic …, 2012 - Wiley Online Library
Purpose: To design, evaluate, and apply a 2D 16‐channel transmit/receive (TX/RX) coil
array tailored for cardiac magnetic resonance imaging (MRI) at 7.0 T. Materials and …
array tailored for cardiac magnetic resonance imaging (MRI) at 7.0 T. Materials and …
Toward cardiovascular MRI at 7 T: clinical needs, technical solutions and research promises
Objective To consider potential clinical needs, technical solutions and research promises of
ultrahigh-field strength cardiovascular MR (CMR). Methods A literature review is given …
ultrahigh-field strength cardiovascular MR (CMR). Methods A literature review is given …
Evolution of UHF body imaging in the human torso at 7T: technology, applications, and future directions
MA Erturk, X Li, PF Van de Moortele… - Topics in Magnetic …, 2019 - journals.lww.com
The potential value of ultrahigh field (UHF) magnetic resonance imaging (MRI) and
spectroscopy to biomedical research and in clinical applications drives the development of …
spectroscopy to biomedical research and in clinical applications drives the development of …
An eight-channel phased array RF coil for spine MR imaging at 7 T
O Kraff, AK Bitz, S Kruszona, S Orzada… - Investigative …, 2009 - journals.lww.com
Objective: To develop a transmit/receive radiofrequency (RF) array for MR imaging of the
human spine at 7 T. The prototype is characterized in simulations and bench measurements …
human spine at 7 T. The prototype is characterized in simulations and bench measurements …
7 Tesla (T) human cardiovascular magnetic resonance imaging using FLASH and SSFP to assess cardiac function: validation against 1.5 T and 3 T.
JJ Suttie, L Delabarre, A Pitcher… - NMR in …, 2012 - Wiley Online Library
We report the first comparison of cardiovascular magnetic resonance imaging (CMR) at 1.5
T, 3 T and 7 T field strengths using steady state free precession (SSFP) and fast low angle …
T, 3 T and 7 T field strengths using steady state free precession (SSFP) and fast low angle …