A literature review of electronic portal imaging for radiotherapy dosimetry

W Van Elmpt, L McDermott, S Nijsten… - Radiotherapy and …, 2008 - Elsevier
Electronic portal imaging devices (EPIDs) have been the preferred tools for verification of
patient positioning for radiotherapy in recent decades. Since EPID images contain dose …

Task Group 142 report: Quality assurance of medical accelerators a

EE Klein, J Hanley, J Bayouth, FF Yin, W Simon… - Medical …, 2009 - Wiley Online Library
The task group (TG) for quality assurance of medical accelerators was constituted by the
American Association of Physicists in Medicine's Science Council under the direction of the …

Developments in electronic portal imaging systems

MC Kirby, AG Glendinning - The British journal of radiology, 2006 - academic.oup.com
Verification of geometric accuracy at the time of treatment delivery has always been a
necessary part of the radiotherapy process. Since the introduction of conformal and intensity …

A quality assurance program for the on‐board

S Yoo, GY Kim, R Hammoud, E Elder… - Medical …, 2006 - Wiley Online Library
To develop a quality assurance (QA) program for the On‐Board Imager (OBI) system and to
summarize the results of these QA tests over extended periods from multiple institutions …

Planning target margin calculations for prostate radiotherapy based on intrafraction and interfraction motion using four localization methods

C Beltran, MG Herman, BJ Davis - International Journal of Radiation …, 2008 - Elsevier
PURPOSE: To determine planning target volume (PTV) margins for prostate radiotherapy
based on the internal margin (IM)(intrafractional motion) and the setup margin …

Application of TG-218 action limits to SRS and SBRT pre-treatment patient specific QA

Y **a, J Adamson, Y Zlateva… - Journal of Radiosurgery …, 2020 - pmc.ncbi.nlm.nih.gov
AAPM TG-218 provides recommendations for standard IMRT pre-treatment QA without
giving specifics for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy …

A global calibration model for EPIDs used for transit dosimetry

S Nijsten, WJC Van Elmpt, M Jacobs… - Medical …, 2007 - Wiley Online Library
Electronic portal imaging devices (EPIDs) are not only applied for patient setup verification
and detection of organ motion but are also increasingly used for dosimetric verification. The …

Experimental verification of a portal dose prediction model

WJC Van Elmpt, S Nijsten, BJ Mijnheer… - Medical …, 2005 - Wiley Online Library
Electronic portal imaging devices (EPIDs) can be used to measure a two‐dimensional (2D)
dose distribution behind a patient, thus allowing dosimetric treatment verification. For this …

Image-guided radiation therapy

XS Qi - An introduction to medical physics, 2017 - Springer
The goal of radiation therapy treatment is to deliver the therapeutic dose to target volumes
while reduce the radiation exposure to the adjacent normal structures. In the past, a large …

Full modulation transfer functions of thick parallel‐and focused‐element scintillator arrays obtained by a Monte Carlo optical transport model

Z Zarrini‐Monfared, S Karbasi, A Zamani… - Medical …, 2023 - Wiley Online Library
Background Arrays of thick segmented crystalline scintillators are useful x‐ray converters for
image‐guided radiation therapy using electronic portal imaging (EPI) and megavoltage …