Simplified monte carlo simulation for Bei**g spectrometer

W Tai-Jie, W Shu-Qin, YAN Wu-Guang, H Yin-Zhi… - Chinese Physics …, 1986‏ - cpc.ihep.ac.cn
The Monte Carlo method based on the functionization of the performance of defectors and
the transformation of values of kinematical variables into" measured" ones by means of …

A Monte-Carlo Generator of Chou-Yang Geometrical Model

D Linkai, C **nyu, Z Qingqi, J Caiiiu, J Guiru - Chinese Physics C, 1988‏ - cpc.ihep.ac.cn
A Monte-Carlo Generator of Chou-Yang Geometrical Model Author Review Editor Contact us
**物理C Chinese Physics C Home Just Accepted Recent Current Issue Archive Special …

[HTML][HTML] Intrabeam scattering of heavy ions at HIRFL-CSR

MAO Li-Jun, Y **ao-Dong, XIA Jia-Wen… - Chinese …, 2007‏ - csnsdoc.ihep.ac.cn
Small-angle multiple intrabeam scattering (IBS) is an important effect for heavy-ion storage
rings with electron cooling, because the cooling time is determined by the equilibrium …

Monte Carlo Simulation of the BEPCⅡ/BEPCⅢ Backgrounds——Touschek Effects

JIN Da-Peng, GUO Ya-Nan, W Yi-Fang… - Chinese Physics …, 2006‏ - cpc.ihep.ac.cn
Motivation of the Touschek backgrounds study is introduced. Also introduced are the theory
and modeling methods of the Touschek effect. The Touschek backgrounds of the main …

Conceptional design of a heavy ion linac injector for HIRFL-CSRm

XH Zhang, YJ Yuan, JW **a, XJ Yin, H Du… - Chinese Physics …, 2014‏ - iopscience.iop.org
A room temperature heavy ion linac has been proposed as a new injector of the main Cooler
Storage Ring (CSRm) at the Heavy Ion Research Facility in Lanzhou (HIRFL), which is …

Neutron dose measurement in carbon ion radiation therapy at HIRFL (IMP)

S You-Wu, L Zong-Qiang, L Wu-Yuan… - Chinese Physics …, 2010‏ - iopscience.iop.org
For radiation protection purposes, the neutron dose in carbon ion radiation therapy at the
HIRFL (Heavy Ion Research Facility in Lanzhou) was investigated. The neutron dose from …

Primary study of Monte Carlo simulation on CdZnTe nuclear detector

REN Shao-Jun, S Wen-Bin, JIN Wei, LI Wan-Wan… - Chinese Physics …, 2004‏ - cpc.ihep.ac.cn
The Monte Carlo simulation software is developed based on the operating principle of
CdZnTe detector, the randomicity of γ ray reaction in the detector and the statistic rule of the …

Monte Carlo Study of Methods for Off-Line Calibration of ARGO-YBJ Experiment

Z Yuan, HE Hui-Hai, MU Jun - Chinese Physics C, 2005‏ - cpc.ihep.ac.cn
In the YBJ-ARGO experiment, the hit time of detector-units can't be calibrated manually due
to the massive number of detector-units. Two methods of off-line calibration, named …

Design of synchrotron for hadron therapy

Z **-Quan, S Ming-Tao, WEI Bao-Wen - Chinese Physics C, 2007‏ - zgwlc.xml-journal.net
According to the operation and development of radiation therapy in the world, in order to
further promote the radiation therapy of tumour in China, a design of a special synchrotron …

A Monte Carlo study on the expansion of hadronic gas in relativistic heavy ion collisions

SS SHI, LS LIU - Chinese Physics C, 2007‏ - hepnp.ihep.ac.cn
According to the hadronization program ART1. 0 of AMPT Monte Carlo generator, the
evolution picture of hadronization process is obtained. The radii of reaction area are then …