Pediatric radiation protection

MT Raissaki - European radiology supplements, 2004 - Springer
Children are more vulnerable to the late somatic effects and genetic effects of radiation than
adults; therefore, every effort should be made to keep the dose as low as reasonably …

Cumulative effective doses delivered by radiographs to preterm infants in a neonatal intensive care unit

J Donadieu, A Zeghnoun, C Roudier, C Maccia… - …, 2006 - publications.aap.org
OBJECTIVE. We sought to determine the number and distribution of radiographs and the
cumulative effective radiograph doses (cED) received by a population of preterm infants …

Dose optimization in pediatric cardiac x‐ray imaging

AJ Gislason, AG Davies, AR Cowen - Medical physics, 2010 - Wiley Online Library
Purpose: The aim of this research was to explore x‐ray beam parameters with intent to
optimize pediatric x‐ray settings in the cardiac catheterization laboratory. This study …

Optimization of a fluoroscope to reduce radiation exposure in pediatric imaging

PH Brown, RD Thomas, PJ Silberberg, LM Johnson - Pediatric radiology, 2000 - Springer
Background. A new children's hospital provided the impetus to investigate radiation dose
and image quality in a fluoroscope that was specially engineered for pediatric fluoroscopy …

Influence of the antiscatter grid on dose and image quality in pediatric interventional cardiology X‐ray systems

C Ubeda, E Vano, L Gonzalez… - Catheterization and …, 2013 - Wiley Online Library
Objective To present a methodology and experimental results to assess the influence, in
terms of dose and image quality, of the antiscatter grid (AG) in a pediatric cardiology X‐ray …

Evaluation of automatic dose rate control for flat panel imaging using a spatial frequency domain figure of merit

M Dehairs, H Bosmans, W Desmet… - Physics in Medicine & …, 2017 - iopscience.iop.org
Current automatic dose rate controls (ADRCs) of dynamic x-ray imaging systems adjust their
acquisition parameters in response to changes in patient thickness in order to achieve a …

Experimental assessment of the influence of beam hardening filters on image quality and patient dose in volumetric 64-slice X-ray CT scanners

MR Ay, A Mehranian, A Maleki, H Ghadiri, P Ghafarian… - Physica Medica, 2013 - Elsevier
Beam hardening filters have long been employed in X-ray Computed Tomography (CT) to
preferentially absorb soft and low-energy X-rays having no or little contribution to image …

Optimizing image quality and dose for digital radiography of distal pediatric extremities using the contrast-to-noise ratio

R Hess, U Neitzel - RöFo-Fortschritte auf dem Gebiet der …, 2012 - thieme-connect.com
Purpose: To investigate the influence of X-ray tube voltage and filtration on image quality in
terms of contrast-to-noise ratio (CNR) and dose for digital radiography of distal pediatric …

Effectiveness of adjusting radiographic technique parameters on image quality in direct digital radiography: a systematic review protocol

C Steffensen, G Trypis, GTW Mander… - JBI Evidence …, 2019 - journals.lww.com
Objective: The purpose of this review is to investigate the effectiveness of adjusting
radiographic technique parameters on image quality of projectional radiographs acquired …

Optimization of radiographic parameters for paediatric cardiac angiography

DGW Onnasch, A Schemm… - The British Journal of …, 2004 - academic.oup.com
In the paediatric cardiac catheterization laboratory the reduction of the radiation dose of
diagnostic and interventional procedures is of high priority. Therefore, we performed an …