Simulation and experimental on thermal behavior of hydrostatic thrust bearing based on superhydrophobic/oleophobic surface

M Guo, G Zhang, H Hu, Z Tian… - Journal of …, 2024 - asmedigitalcollection.asme.org
The temperature rises of the oil film in hydrostatic bearings at high speed lead to a reduction
in load capacity, accuracy, and stability. In this paper, a superhydrophobic/oleophobic …

[PDF][PDF] The characteristics of increased pressure drop in pipes with grooves

PW Sunu - Advanced Studies in Theoretical Physics, 2015 - m-hikari.com
The aim of this study was to investigate the characteristic of increased pressure drop in
grooved straight pipes. The observation has been done at number of groove of 9, 25 and …

Heat transfer enhancement and pressure drop of grooved annulus of double pipe heat exchanger

PW Sunu, IM Rasta - Acta Polytechnica, 2017 - ojst.is.cvut.cz
This investigation was performed to experimentally investigate the enhancement of heat
transfer and the friction of an annulus in a double pipe heat exchanger system with …

Study of thermal effectiveness in shell and helically coiled tube heat exchanger with addition nanoparticles

PW Sunu, DS Anakottapary, IDM Susila… - Journal of Physics …, 2020 - iopscience.iop.org
Thermal effectiveness was performed as preliminary research in shell and coiled tube heat
exchanger with addition of Al 2 O 3 nanoparticles. In the present study, the effect of small …

[PDF][PDF] Optimal grooves number for reducing pressure drop

PW Sunu, ING Wardana, AA Sonief… - Contemporary …, 2016 - m-hikari.com
Optimal rectangular grooves number on internal wall surface of pipe for reducing pressure
drop and drag has been investigated experimentally. The change of pressure drop and drag …

Experimental studies on grooved double pipe heat exchanger with different groove space

PW Sunu, IM Arsawan, DS Anakottapary… - Journal of Physics …, 2018 - iopscience.iop.org
Experimental studies were performed on grooved double pipe heat exchanger (DPHE) with
different groove space. The objective of this work is to determine optimal heat transfer …

Effect of Various Superheat Condition on Working Condition of Air Cooled Chiller

PW Sunu, DA Simon, IM Rasta… - … on Applied Science …, 2018 - ieeexplore.ieee.org
Application of energy efficient chiller, compressor, air handling unit, evaporator etc are some
indicators of the energy conservation in Heating, Ventilating, and Air Conditioning (HVAC) …

Efectifitas Perpindahan Panas Pada Double Pipe Heat Exchanger dengan Groove

PW Sunu, DS Anakottapary, I Santika - 2015 - repository.pnb.ac.id
Perpindahan panas pada double pipe heat exchanger dengan groove diteliti dengan
metode eksperimen di laboratorium. Penelitian ini bertujuan untuk mengungkap fenomena …

Approach temperature of heating process in double tube heat exchanger with Al2O3-water nanofluid

DS Anakottapary, A Wibolo, PW Sunu… - Advanced Science …, 2017 - ingentaconnect.com
The approach temperature of heating process in double tube heat exchanger with Al2O3-
water nanofluid under turbulent flow regime have been studied. This investigation were …

A brief comparative thermodynamics review of domestic air conditioning system with or without installed heat recovery

PW Sunu, DS Anakottapary, IW Suirya… - Journal of Physics …, 2020 - iopscience.iop.org
With the increase of mean all season temperature in many cities and demand of hot water
for domestic used, high energy consumption of cooling system and electricity are rising …