Stability-oriented impedance modeling, analysis, and sha** for power supply system in more-electric aircraft: a review
More-electric aircraft (MEA) has evolved in the recent two decades due to their superiority in
fuel efficiency, noise reduction, and reliability compared to conventional aircraft. The power …
fuel efficiency, noise reduction, and reliability compared to conventional aircraft. The power …
A model predictive control strategy for performance improvement of hybrid energy storage systems in DC microgrids
Filtration-based (FB) power/current allocation of battery-supercapacitor (SC) hybrid energy
storage systems (HESSs) is the most common approach in DC microgrid (MG) applications …
storage systems (HESSs) is the most common approach in DC microgrid (MG) applications …
Active dam** stabilization techniques for cascaded systems in DC microgrids: A comprehensive review
Microgrids have arisen as an alternate solution to the problem of power generation in
distributed energy. Compared to ac microgrids, dc microgrids (DC MGs) are superior in …
distributed energy. Compared to ac microgrids, dc microgrids (DC MGs) are superior in …
A power adaptive impedance resha** strategy for cascaded DC system with buck-type constant power load
It is well-known that the low-frequency negative input impedance of the constant power load
(CPL) is the major cause of the cascaded system instability, and the heavier the power, the …
(CPL) is the major cause of the cascaded system instability, and the heavier the power, the …
Active dam** method for LC-DAB system based on a power-based impedance model
Y Chen, Y Zhang, E Qu, M He - IEEE Transactions on Power …, 2022 - ieeexplore.ieee.org
A cascaded system, consisting of an LC filter and a dual active bridge (DAB), can exhibit
certain instability due to terminal impedance mismatch. In this regard, the existing …
certain instability due to terminal impedance mismatch. In this regard, the existing …
Adaptive dam** control to enhance small-signal stability of DC microgrids
This article proposes an adaptive active control approach for dam** the low-frequency
oscillations in a dc microgrid (DC-MG). The DC-MG is comprised of hybrid power sources …
oscillations in a dc microgrid (DC-MG). The DC-MG is comprised of hybrid power sources …
A combined bus port impedance based stability criterion for DC distribution power systems
The impedance-based criteria are well known to assess the stability of DC systems by
impedance measurement method. However, these criteria apply to the DC systems with the …
impedance measurement method. However, these criteria apply to the DC systems with the …
A Virtual Impedance-Based Active Dam** Control Strategy for Triple Active Bridge Converter
Multiport dc–dc converters have been intensively concerned and studied in power
electronics-based systems. However, the instability issue and its suppression method are …
electronics-based systems. However, the instability issue and its suppression method are …
[HTML][HTML] A virtual adaptive RC damper control method to suppress voltage oscillation in DC microgrid
In DC Microgrid tightly regulated load converters operate as a constant power load (CPL).
CPLs have negative incremental resistance characteristics, which leads to voltage …
CPLs have negative incremental resistance characteristics, which leads to voltage …
Mismatched Disturbance Compensation Enhanced Robust H Control for the DC-DC Boost Converter Feeding Constant Power Loads
A new control scheme to enhance the robustness and disturbance rejection ability of a DC-
DC boost converter feeding constant power loads (CPLs) is proposed in this paper via …