Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Assessment of hip and knee joints and implants using acoustic emission monitoring: A sco** review
Objectives: Population ageing and the subsequent increase of joint disorders prevalence
requires the development of non-invasive and early diagnostic methods to enable timely …
requires the development of non-invasive and early diagnostic methods to enable timely …
A systematic review of imageless hand-held robotic-assisted knee arthroplasty: learning curve, accuracy, functional outcome and survivorship
ND Clement, M Al-Zibari, I Afzal… - EFORT open …, 2020 - eor.bioscientifica.com
The aim of this systematic review was to present and assess the quality of evidence for
learning curve, component positioning, functional outcomes and implant survivorship for …
learning curve, component positioning, functional outcomes and implant survivorship for …
Metaphyseal cones in revision total knee arthroplasty: the role of stems
Aims Metaphyseal tritanium cones can be used to manage the tibial bone loss commonly
encountered at revision total knee arthroplasty (rTKA). Tibial stems provide additional …
encountered at revision total knee arthroplasty (rTKA). Tibial stems provide additional …
Tibial shape and size predicts the risk of tibial plateau fracture after cementless unicompartmental knee arthroplasty in Japanese patients: A multicentre study
T Hiranaka, R Yoshikawa, K Yoshida… - The Bone & Joint …, 2020 - boneandjoint.org.uk
Aims Cementless unicompartmental knee arthroplasty (UKA) has advantages over
cemented UKA, including improved fixation, but has a higher risk of tibial plateau fracture …
cemented UKA, including improved fixation, but has a higher risk of tibial plateau fracture …
Robotic-assisted unicompartmental knee arthroplasty has a greater early functional outcome when compared to manual total knee arthroplasty for isolated medial …
ND Clement, A Bell, P Simpson… - Bone & Joint …, 2020 - boneandjoint.org.uk
Aims The primary aim of the study was to compare the knee-specific functional outcome of
robotic unicompartmental knee arthroplasty (rUKA) with manual total knee arthroplasty …
robotic unicompartmental knee arthroplasty (rUKA) with manual total knee arthroplasty …
Ten-year survival and patient-reported outcomes of a medial unicompartmental knee arthroplasty incorporating an all-polyethylene tibial component
Introduction Biomechanical studies have suggested that proximal tibial strain is elevated in
UKAs incorporating all-polyethylene tibial components with concern that this leads to …
UKAs incorporating all-polyethylene tibial components with concern that this leads to …
Finite element analysis of medial closing and lateral opening wedge osteotomies of the distal femur in relation to hinge fractures
Purpose Intraoperative hinge fractures in distal femur osteotomies represent a risk factor for
loss of alignment and non-union. Using finite element analysis, the goal of this study was to …
loss of alignment and non-union. Using finite element analysis, the goal of this study was to …
The effect of malalignment on proximal tibial strain in fixed-bearing unicompartmental knee arthroplasty: a comparison between metal-backed and all-polyethylene …
Objectives Elevated proximal tibial bone strain may cause unexplained pain, an important
cause of unicompartmental knee arthroplasty (UKA) revision. This study investigates the …
cause of unicompartmental knee arthroplasty (UKA) revision. This study investigates the …
Mid-term outcomes of medial metal backed and all-polyethylene unicompartmental knee arthroplasty in obese patients: a retrospective propensity-matched analysis
L De Berardinis, G Piovan, D Screpis… - Journal of Orthopaedic …, 2024 - Springer
Background This retrospective study compares the outcomes of unicompartmental medial
fixed-bearing knee arthroplasty (mUKA), involving a cemented metal-backed (MB) or an all …
fixed-bearing knee arthroplasty (mUKA), involving a cemented metal-backed (MB) or an all …
Optimal interference of the tibial component of the cementless Oxford Unicompartmental Knee Replacement
S Campi, SJ Mellon, D Ridley, B Foulke… - Bone & Joint …, 2018 - boneandjoint.org.uk
Objectives The primary stability of the cementless Oxford Unicompartmental Knee
Replacement (OUKR) relies on interference fit (or press fit). Insufficient interference may …
Replacement (OUKR) relies on interference fit (or press fit). Insufficient interference may …