[HTML][HTML] Multi-Stage ANN Model for Optimizing the Configuration of External Lightning Protection and Grounding Systems
This paper proposes an Artificial Neural Network (ANN) model using a Multi-Stage method
to optimize the configuration of an External Lightning Protection System (ELPS) and …
to optimize the configuration of an External Lightning Protection System (ELPS) and …
[HTML][HTML] Lightning flashover characteristics of a full-scale AC 500 kV transmission tower with composite cross arms
Overhead transmission lines (OTLs) have always been the major means of power delivery.
With the significant increase of transmission voltage and transmission capacity, the …
With the significant increase of transmission voltage and transmission capacity, the …
Study on space charge characteristics in XLPE under DC voltage superimposed by impulse voltage
X Wang, Q Jiang, C Wu, S Liu… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
In direct current (dc) transmission lines, power cables are susceptible to the invasion of
switching overvoltage or lightning overvoltage. This causes the accumulation of space …
switching overvoltage or lightning overvoltage. This causes the accumulation of space …
Investigative analysis of the impact of the climatic induced pollution upon the insulators in 500 kV HVDC transmission line
The increasing effect of climatic change has mandated the investigation of its negative
impact upon electrical power systems. One of the most vulnerable parts of the power system …
impact upon electrical power systems. One of the most vulnerable parts of the power system …
A comprehensive VSG-based onshore FRT control strategy for OWFs with VSC-MT-HVDC transmission
This paper proposes a communication-free control strategy at the offshore wind farm (OWF)
level to enhance onshore fault ride-through (FRT) grid code compliance of the voltage …
level to enhance onshore fault ride-through (FRT) grid code compliance of the voltage …
[HTML][HTML] Surge arrester allocation for lightning protection of VSC based HVDC prototype
High-voltage direct current (HVDC) systems, based on voltage source converters (VSC),
enable asynchronous interconnection of grids with different frequencies and contribute to …
enable asynchronous interconnection of grids with different frequencies and contribute to …
Assessment of the hazard risks on HVDC transmission networks due to lightning strikes and faults
A Said, M Galal, MA Abd-Allah - PloS one, 2024 - journals.plos.org
HVDC systems with high voltage and direct current are suitable for reducing electricity
losses, during transmission over long distances. However, HVDC lines have the highest …
losses, during transmission over long distances. However, HVDC lines have the highest …
Analysis of Lightning Transient characteristics of short-length mixed MMC-MVDC transmission system
Medium voltage direct current (MVDC) transmission system are growing due to their
assistive quality in conventional grid and compatibility with renewable power network …
assistive quality in conventional grid and compatibility with renewable power network …
Assessment of overvoltage and insulation coordination in mixed HVDC transmission lines exposed to lightning strikes
Many geographical constraints and aesthetic concerns necessitate the partial use of cable
sections in the High Voltage DC (HVDC) transmission line, resulting in a mixed transmission …
sections in the High Voltage DC (HVDC) transmission line, resulting in a mixed transmission …
Mono-pole blocking accident analysis caused by inaccurate measurement of optical CT in±800 kV UHVDC transmission system under lightning strike
The ultra-high voltage direct current (UHVDC) power transmission systems usually transmit
a capacity of 6-8 GW, their stability and reliability are of vital importance to the large power …
a capacity of 6-8 GW, their stability and reliability are of vital importance to the large power …