Towards nanoscale electrical measurements in liquid by advanced KPFM techniques: a review
Fundamental mechanisms of energy storage, corrosion, sensing, and multiple biological
functionalities are directly coupled to electrical processes and ionic dynamics at solid–liquid …
functionalities are directly coupled to electrical processes and ionic dynamics at solid–liquid …
Scanning Kelvin probe microscopy: challenges and perspectives towards increased application on biomaterials and biological samples
We report and comment on the possible increase of application of scanning Kelvin probe
microscopy (SKPM) for biomaterials, biological substrates, and biological samples. First, the …
microscopy (SKPM) for biomaterials, biological substrates, and biological samples. First, the …
Impact of Monovalent Cation Halide Additives on the Structural and Optoelectronic Properties of CH3NH3PbI3 Perovskite
The influence of monovalent cation halide additives on the optical, excitonic, and electrical
properties of CH3NH3PbI3 perovskite is reported. Monovalent cation halide with similar …
properties of CH3NH3PbI3 perovskite is reported. Monovalent cation halide with similar …
The electronic structure of metal oxide/organo metal halide perovskite junctions in perovskite based solar cells
Cross-sections of a hole-conductor-free CH3NH3PbI3 perovskite solar cell were
characterized with Kelvin probe force microscopy. A depletion region width of about 45 nm …
characterized with Kelvin probe force microscopy. A depletion region width of about 45 nm …
Application of AFM-based techniques in studies of corrosion and corrosion inhibition of metallic alloys
K Yasakau - Corrosion and Materials Degradation, 2020 - mdpi.com
In this review several scanning probe microscopy techniques are briefly discussed as
valuable assets for corrosionists to study corrosion susceptibility and inhibition of metals and …
valuable assets for corrosionists to study corrosion susceptibility and inhibition of metals and …
Fermi level alignment by copper do** for efficient ITO/perovskite junction solar cells
Different from band edge alignment, the Fermi level mismatch induced by band bending can
manipulate charge collection at the ITO/(CH3NH3) 1− xCuxPbI3 heterojunctions. In this …
manipulate charge collection at the ITO/(CH3NH3) 1− xCuxPbI3 heterojunctions. In this …
[HTML][HTML] Effect of contaminations and surface preparation on the work function of single layer MoS2
O Ochedowski, K Marinov… - Beilstein journal of …, 2014 - beilstein-journals.org
Thinning out MoS 2 crystals to atomically thin layers results in the transition from an indirect
to a direct bandgap material. This makes single layer MoS 2 an exciting new material for …
to a direct bandgap material. This makes single layer MoS 2 an exciting new material for …
Quantification of in-contact probe-sample electrostatic forces with dynamic atomic force microscopy
Atomic force microscopy (AFM) methods utilizing resonant mechanical vibrations of
cantilevers in contact with a sample surface have shown sensitivities as high as few …
cantilevers in contact with a sample surface have shown sensitivities as high as few …
Reconstruction of surface potential from Kelvin probe force microscopy images
G Cohen, E Halpern, SU Nanayakkara… - …, 2013 - iopscience.iop.org
We present an algorithm for reconstructing a sample surface potential from its Kelvin probe
force microscopy (KPFM) image. The measured KPFM image is a weighted average of the …
force microscopy (KPFM) image. The measured KPFM image is a weighted average of the …
Multiscale approach for simulations of Kelvin probe force microscopy with atomic resolution
The distance dependence and atomic-scale contrast recently observed in nominal contact
potential difference (CPD) signals simultaneously recorded by Kelvin probe force …
potential difference (CPD) signals simultaneously recorded by Kelvin probe force …