Dosimetry of small static fields used in external photon beam radiotherapy: summary of TRS‐483, the IAEA–AAPM international Code of Practice for reference and …
Purpose A joint IAEA/AAPM international working group has developed a Code of Practice
(CoP) for the dosimetry of small static fields used in external megavoltage photon beam …
(CoP) for the dosimetry of small static fields used in external megavoltage photon beam …
Review of plastic and liquid scintillation dosimetry for photon, electron, and proton therapy
While scintillation dosimetry has been around for decades, the need for a dosimeter tailored
to the reality of modern radiation therapy—in particular a real-time, water-equivalent, energy …
to the reality of modern radiation therapy—in particular a real-time, water-equivalent, energy …
Report of AAPM Task Group 155: megavoltage photon beam dosimetry in small fields and non‐equilibrium conditions
Small‐field dosimetry used in advance treatment technologies poses challenges due to loss
of lateral charged particle equilibrium (LCPE), occlusion of the primary photon source, and …
of lateral charged particle equilibrium (LCPE), occlusion of the primary photon source, and …
Needs, trends, and advances in scintillators for radiographic imaging and tomography
Radiographic imaging and tomography (RadIT), which started with Röntgen's seminal X-ray
work in 1895, now includes an increasing number of IT modalities. In addition to the original …
work in 1895, now includes an increasing number of IT modalities. In addition to the original …
Application of the Exradin W1 scintillator to determine Ediode 60017 and microDiamond 60019 correction factors for relative dosimetry within small MV and FFF fields
TSA Underwood, BC Rowland, R Ferrand… - Physics in Medicine …, 2015 - iopscience.iop.org
In this work we use EBT3 film measurements at 10 MV to demonstrate the suitability of the
Exradin W1 (plastic scintillator) for relative dosimetry within small photon fields. We then use …
Exradin W1 (plastic scintillator) for relative dosimetry within small photon fields. We then use …
On the correction, perturbation and modification of small field detectors in relative dosimetry
The purpose of this study was to derive a complete set of correction and perturbation factors
for output factors (OF) and dose profiles. Modern small field detectors were investigated …
for output factors (OF) and dose profiles. Modern small field detectors were investigated …
A novel method for the determination of field output factors and output correction factors for small static fields for six diodes and a microdiamond detector in …
Purpose The goal of this work is to provide a large and consistent set of data for detector‐
specific output correction factors,, for small static fields for seven solid‐state detectors and to …
specific output correction factors,, for small static fields for seven solid‐state detectors and to …
The international commission on radiation units and measurements
HG Menzel - Journal of the ICRU, 2012 - journals.sagepub.com
The International Commission on Radiation Units and Measurements - Hans-Georg Menzel,
2012 Skip to main content Scheduled maintenance on Monday, November 20th, with …
2012 Skip to main content Scheduled maintenance on Monday, November 20th, with …
Characterization of the plastic scintillation detector Exradin W2 for small field dosimetry
Purpose Small field dosimetry has been an active area of research for over a decade. It is
now known that large dosimetric errors can be introduced if proper detectors or correction …
now known that large dosimetric errors can be introduced if proper detectors or correction …
Monte Carlo simulated corrections for beam commissioning measurements with circular and MLC shaped fields on the CyberKnife M6 System: a study including diode …
P Francescon, W Kilby, JM Noll, L Masi… - Physics in Medicine …, 2017 - iopscience.iop.org
Monte Carlo simulation was used to calculate correction factors for output factor (OF),
percentage depth-dose (PDD), and off-axis ratio (OAR) measurements with the CyberKnife …
percentage depth-dose (PDD), and off-axis ratio (OAR) measurements with the CyberKnife …