Development of a Compton camera based on 3D position-sensitive virtual Frisch-grid CZT detectors
Y Kim, W Lee - Nuclear Instruments and Methods in Physics Research …, 2023 - Elsevier
In this study, a Compton camera was developed utilizing a 2× 2 array of cadmium–zinc–
telluride (CZT) detectors. The camera employs four CZTs, each measuring 6 mm× 6 mm× 19 …
telluride (CZT) detectors. The camera employs four CZTs, each measuring 6 mm× 6 mm× 19 …
Front-end ASIC for spectroscopic readout of virtual Frisch-grid CZT bar sensors
E Vernon, G De Geronimo, A Bolotnikov… - Nuclear Instruments and …, 2019 - Elsevier
Compact multi-channel radiation detectors rely on low noise front-end application specific
integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed …
integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed …
[HTML][HTML] Positional correction of a 3D position-sensitive virtual Frisch-grid CZT detector for gamma spectroscopy and imaging based on a theoretical assumption
Y Kim, K Shin, A Bolotnikov, W Lee - Nuclear Engineering and Technology, 2023 - Elsevier
The virtual Frisch-grid method for room-temperature radiation detectors has been widely
used because of its simplicity and high performance. Recently, side electrodes were …
used because of its simplicity and high performance. Recently, side electrodes were …
Position-sensitive virtual frisch-grid detectors for imaging and spectroscopy of gamma rays
AE Bolotnikov, RB James - Radiation Detection Systems, 2021 - taylorfrancis.com
The position-sensitive virtual Frisch-grid (VFG) detector is a kind of radiation detector
specifically designed for utilizing large-volume CdZnTe (CZT) crystals, often ones containing …
specifically designed for utilizing large-volume CdZnTe (CZT) crystals, often ones containing …
Room temperature semiconductor radiation detectors based on CdZnTe and CdZnTeSe
M Sajjad - 2020 - search.proquest.com
In recent years, there have been considerable interests in nuclear radiation detectors for
national security and nuclear safeguard including monitoring special nuclear materials and …
national security and nuclear safeguard including monitoring special nuclear materials and …
Design and Characterization of an Advanced Virtual Frisch-grid Application Specific Integrated Circuit for Gamma Ray Spectroscopy and a Low Noise Multi-amplifier …
E Vernon - 2019 - search.proquest.com
Compact radiation detection systems with high channel integration rely on low noise front-
end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here …
end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here …