AAPM TG 191: Clinical use of luminescent dosimeters: TLDs and OSLDs
Thermoluminescent dosimeters (TLD) and optically stimulated luminescent dosimeters
(OSLD) are practical, accurate, and precise tools for point dosimetry in medical physics …
(OSLD) are practical, accurate, and precise tools for point dosimetry in medical physics …
Highlights and pitfalls of 20 years of application of computerised glow curve analysis to thermoluminescence research and dosimetry
The technical and dosimetric aspects of computerised glow curve analysis are described in
detail including a review of the current 'state-of-the-achieved'in applications to …
detail including a review of the current 'state-of-the-achieved'in applications to …
Attenuation parameters of HDPE filled with different nano-size and bulk WO3 for X-ray shielding applications
A Obeid, HEL Balaa, OEL Samad, R Awad… - … Physical Journal Plus, 2022 - epjplus.epj.org
High-density polyethylene (HDPE) was obtained through a compression molding technique,
and incorporated with different filler weight fractions (10, 15, 25, and 35%) of bulk WO3, and …
and incorporated with different filler weight fractions (10, 15, 25, and 35%) of bulk WO3, and …
Thermoluminescent characteristics of LiF: Mg, Cu, P and CaSO4: Dy for low dose measurement
Thermoluminescence (TL) characteristics for LiF: Mg, Cu, P, and CaSO 4: Dy under the
homogeneous field of X-ray beams of diagnostic irradiation and its verification using …
homogeneous field of X-ray beams of diagnostic irradiation and its verification using …
Supplement 2 for the 2004 update of the AAPM Task Group No. 43 Report: joint recommendations by the AAPM and GEC‐ESTRO
Since the publication of the 2004 update to the American Association of Physicists in
Medicine (AAPM) Task Group No. 43 Report (TG‐43U1) and its 2007 supplement (TG …
Medicine (AAPM) Task Group No. 43 Report (TG‐43U1) and its 2007 supplement (TG …
On the experimental validation of model-based dose calculation algorithms for 192Ir HDR brachytherapy treatment planning
There is an acknowledged need for the design and implementation of physical phantoms
appropriate for the experimental validation of model-based dose calculation algorithms …
appropriate for the experimental validation of model-based dose calculation algorithms …
Influence of phantom materials on the energy dependence of LiF: Mg, Ti thermoluminescent dosimeters exposed to 20–300 kV narrow x-ray spectra, 137Cs and 60Co …
G Massillon-Jl, A Cabrera-Santiago… - Physics in Medicine …, 2014 - iopscience.iop.org
Abstract LiF: Mg, Ti, are widely used to estimate absorbed-dose received by patients during
diagnostic or medical treatment. Conveniently, measurements are usually made in plastic …
diagnostic or medical treatment. Conveniently, measurements are usually made in plastic …
Determination of intrinsic energy dependence of point‐like inorganic scintillation detector in brachytherapy
P Georgi, ÅC Tedgren, L Persson… - Medical …, 2024 - Wiley Online Library
Abstract Background Inorganic scintillation detectors (ISDs) are promising for in vivo
dosimetry in brachytherapy (BT). ISDs have fast response, providing time resolved dose rate …
dosimetry in brachytherapy (BT). ISDs have fast response, providing time resolved dose rate …
Characterization of nanoDot optically stimulated luminescence detectors and high‐sensitivity MCP‐N thermoluminescent detectors in the 40–300 kV p energy range
Y Poirier, S Kuznetsova… - Medical physics, 2018 - Wiley Online Library
Purpose To investigate empirically the energy dependence of the detector response of two
in vivo luminescence detectors, LiF: Mg, Cu, P (MCP‐N) high‐sensitivity TLD s and Al2O3: C …
in vivo luminescence detectors, LiF: Mg, Cu, P (MCP‐N) high‐sensitivity TLD s and Al2O3: C …
Response of TL and OSL passive personal dosimetry systems in poly-energetic and multi-directional photon radiation fields
FH Apostolakopoulos, N Kržanović, K Stanković… - Applied Radiation and …, 2019 - Elsevier
The aim of this paper is to examine the energy and angular responses of thermoluminescent
dosimeters containing either MTS-N (LiF: Mg, Ti) or MCP-N (LiF: Mg, Cu, P) detector …
dosimeters containing either MTS-N (LiF: Mg, Ti) or MCP-N (LiF: Mg, Cu, P) detector …