Multiscale X-ray tomography of cementitious materials: A review

S Brisard, M Serdar, PJM Monteiro - Cement and Concrete Research, 2020 - Elsevier
X-ray computed tomography (CT) is a non-destructive technique that offers a 3D insight into
the microstructure of thick (opaque) samples with virtually no preliminary sample …

Metal artifact reduction in CT: where are we after four decades?

L Gjesteby, B De Man, Y **, H Paganetti… - Ieee …, 2016 - ieeexplore.ieee.org
Methods to overcome metal artifacts in computed tomography (CT) images have been
researched and developed for nearly 40 years. When X-rays pass through a metal object …

Convolutional neural network based metal artifact reduction in X-ray computed tomography

Y Zhang, H Yu - IEEE transactions on medical imaging, 2018 - ieeexplore.ieee.org
In the presence of metal implants, metal artifacts are introduced to x-ray computed
tomography CT images. Although a large number of metal artifact reduction (MAR) methods …

Deep sinogram completion with image prior for metal artifact reduction in CT images

L Yu, Z Zhang, X Li, L **ng - IEEE transactions on medical …, 2020 - ieeexplore.ieee.org
Computed tomography (CT) has been widely used for medical diagnosis, assessment, and
therapy planning and guidance. In reality, CT images may be affected adversely in the …

DuDoDR-Net: Dual-domain data consistent recurrent network for simultaneous sparse view and metal artifact reduction in computed tomography

B Zhou, X Chen, SK Zhou, JS Duncan, C Liu - Medical Image Analysis, 2022 - Elsevier
Sparse-view computed tomography (SVCT) aims to reconstruct a cross-sectional image
using a reduced number of x-ray projections. While SVCT can efficiently reduce the radiation …

Deep learning–based metal artefact reduction in PET/CT imaging

H Arabi, H Zaidi - European radiology, 2021 - Springer
Objectives The susceptibility of CT imaging to metallic objects gives rise to strong streak
artefacts and skewed information about the attenuation medium around the metallic …

DuDoUFNet: dual-domain under-to-fully-complete progressive restoration network for simultaneous metal artifact reduction and low-dose CT reconstruction

B Zhou, X Chen, H **e, SK Zhou… - IEEE transactions on …, 2022 - ieeexplore.ieee.org
To reduce the potential risk of radiation to the patient, low-dose computed tomography
(LDCT) has been widely adopted in clinical practice for reconstructing cross-sectional …

Clinical evaluation of the iterative metal artifact reduction algorithm for CT simulation in radiotherapy

M Axente, A Paidi, R Von Eyben, C Zeng… - Medical …, 2015 - Wiley Online Library
Purpose: To clinically evaluate an iterative metal artifact reduction (IMAR) algorithm
prototype in the radiation oncology clinic setting by testing for accuracy in CT number …

Influence of acquisition parameters on the magnitude of cone beam computed tomography artifacts

DQ Freitas, RC Fontenele… - Dentomaxillofacial …, 2018 - academic.oup.com
Aim: To evaluate the influence of kilovoltage (kVp) and metal artifact reduction tool (MAR) on
the magnitude of cone beam CT (CBCT) artifacts. Methods: A titanium and zirconia implants …

Metal about the hip and artifact reduction techniques: from basic concepts to advanced imaging

I Khodarahmi, A Isaac, EK Fishman… - Seminars in …, 2019 - thieme-connect.com
Promising outcomes of hip replacement interventions in this era of aging populations have
led to higher demands for hip arthroplasty procedures. These require effective methods and …