Modeling and stability issues of voltage-source converter-dominated power systems: A review

L **ong, X Liu, Y Liu, F Zhuo - CSEE Journal of Power and …, 2020‏ - ieeexplore.ieee.org
With the substantive increase in the proportion of voltage-source converter (VSC)-based
equipment, traditional power systems that primarily constituted of synchronous generators …

Protection of AC microgrid integrated with renewable energy sources–A research review and future trends

A Chandra, GK Singh, V Pant - Electric Power Systems Research, 2021‏ - Elsevier
The addition of distributed generation to a power system improves its performance. It makes
it more sustainable and efficient. But it also poses substantial challenges for designing a …

Dynamic modeling of networks, microgrids, and renewable sources in the dq0 reference frame: A survey

D Baimel, J Belikov, JM Guerrero, Y Levron - Ieee Access, 2017‏ - ieeexplore.ieee.org
With increasing the penetration of distributed and renewable sources into power grids, and
with increasing the use of power electronics-based devices, the dynamic behavior of large …

Impact of power-electronic sources on transmission line ground fault protection

M Nagpal, C Henville - IEEE Transactions on Power Delivery, 2017‏ - ieeexplore.ieee.org
Power-electronic sources, such as Type 3 wind turbine generators and static synchronous
compensators (STATCOM), interface to the grid through, partial-or full-scale, and power …

Mitigation of SSR by embedding subsynchronous notch filters into DFIG converter controllers

H Liu, X **e, Y Li, H Liu, Y Hu - IET Generation, Transmission & …, 2017‏ - Wiley Online Library
The interaction between controllers of doubly fed induction generators (DFIGs) and fixed
series compensations may cause a new type of subsynchronous resonance (SSR), namely …

Analysis and mitigation of SSCI in DFIG systems with experimental validation

MT Ali, D Zhou, Y Song, M Ghandhari… - IEEE Transactions …, 2019‏ - ieeexplore.ieee.org
Sub-synchronous oscillations (SSOs) in doubly-fed induction generator (DFIG)-based series
compensated power systems are mainly caused by sub-synchronous control interaction …

Multi-scale modeling and simulation of DFIG-based wind energy conversion system

Y **a, Y Chen, Y Song, K Strunz - IEEE Transactions on Energy …, 2019‏ - ieeexplore.ieee.org
A multi-scale transients model of a doubly fed induction generator (DFIG)-based wind
energy conversion system (WECS) is developed, implemented, and validated. All ac circuit …

Dynamic phasor based interface model for EMT and transient stability hybrid simulations

D Shu, X **e, V Dinavahi, C Zhang… - IEEE Transactions on …, 2017‏ - ieeexplore.ieee.org
Electromagnetic transient (EMT) and transient stability hybrid simulations are predominantly
used to analyze the interactions between HVDC systems and the ac grids. However, the …

An accurate type III wind turbine generator short circuit model for protection applications

T Kauffmann, U Karaagac, I Kocar… - … on Power Delivery, 2016‏ - ieeexplore.ieee.org
The integration of renewables into power systems introduces several technical challenges
including the development of appropriate models for system protection studies and accurate …

Distance protection for transmission lines of DFIG-based wind power integration system

Y Chen, M Wen, X Yin, Y Cai, J Zheng - International Journal of Electrical …, 2018‏ - Elsevier
This paper proposes a distance relay in time domain based on the RL differential-equation
algorithm which is suitable for wind power integration system. However, the conventional RL …