Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Contemporary carotid imaging: from degree of stenosis to plaque vulnerability
W Brinjikji, J Huston, AA Rabinstein, GM Kim… - Journal of …, 2016 - thejns.org
Carotid artery stenosis is a well-established risk factor of ischemic stroke, contributing to up
to 10%-20% of strokes or transient ischemic attacks. Many clinical trials over the last 20 …
to 10%-20% of strokes or transient ischemic attacks. Many clinical trials over the last 20 …
SMASH, SENSE, PILS, GRAPPA: how to choose the optimal method
M Blaimer, F Breuer, M Mueller… - Topics in Magnetic …, 2004 - journals.lww.com
Fast imaging methods and the availability of required hardware for magnetic resonance
tomography (MRT) have significantly reduced acquisition times from about an hour down to …
tomography (MRT) have significantly reduced acquisition times from about an hour down to …
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
In this study, a novel partially parallel acquisition (PPA) method is presented which can be
used to accelerate image acquisition using an RF coil array for spatial encoding. This …
used to accelerate image acquisition using an RF coil array for spatial encoding. This …
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
A new approach to autocalibrating, coil‐by‐coil parallel imaging reconstruction, is
presented. It is a generalized reconstruction framework based on self‐consistency. The …
presented. It is a generalized reconstruction framework based on self‐consistency. The …
Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi‐slice imaging
FA Breuer, M Blaimer, RM Heidemann… - … in Medicine: An …, 2005 - Wiley Online Library
In all current parallel imaging techniques, aliasing artifacts resulting from an undersampled
acquisition are removed by means of a specialized image reconstruction algorithm. In this …
acquisition are removed by means of a specialized image reconstruction algorithm. In this …
Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA)
FA Breuer, M Blaimer, MF Mueller… - … in Medicine: An …, 2006 - Wiley Online Library
Abstract The CAIPIRINHA (Controlled Aliasing In Parallel Imaging Results IN Higher
Acceleration) concept in parallel imaging has recently been introduced, which modifies the …
Acceleration) concept in parallel imaging has recently been introduced, which modifies the …
Parallel magnetic resonance imaging
DJ Larkman, RG Nunes - Physics in Medicine & Biology, 2007 - iopscience.iop.org
Parallel imaging has been the single biggest innovation in magnetic resonance imaging in
the last decade. The use of multiple receiver coils to augment the time consuming Fourier …
the last decade. The use of multiple receiver coils to augment the time consuming Fourier …
Joint image reconstruction and sensitivity estimation in SENSE (JSENSE)
Parallel magnetic resonance imaging (pMRI) using multichannel receiver coils has emerged
as an effective tool to reduce imaging time in various applications. However, the issue of …
as an effective tool to reduce imaging time in various applications. However, the issue of …
Point spread function map** with parallel imaging techniques and high acceleration factors: Fast, robust, and flexible method for echo‐planar imaging distortion …
Echo‐planar imaging (EPI) is an ultrafast magnetic resonance (MR) imaging technique
prone to geometric distortions. Various correction techniques have been developed to …
prone to geometric distortions. Various correction techniques have been developed to …
Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA)
Current parallel imaging techniques for accelerated imaging require a fully encoded
reference data set to estimate the spatial coil sensitivity information needed for …
reference data set to estimate the spatial coil sensitivity information needed for …