Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Analisis Kekuatan Tekan Selubung Komposit Laminat E-glass pada Beton Kolom Silinder dengan Metode Vacuum Bagging
This study aims to obtain the average compressive strength of cylindrical column concrete
specimens reinforced with an e-glass fiber laminate composite wrap based on variations in …
specimens reinforced with an e-glass fiber laminate composite wrap based on variations in …
Analisis Kekuatan Tekan Beton Kolom Silinder Diperkuat Komposit Hibrid Laminat Jute E-Glass Epoksi
Tujuan penelitian ini ialah analisis perubahan massa dan ukuran diameter rata-rata
spesimen beton kolom silinder (BKS) yang dilapisi oleh komposit hibrid laminat jute glass …
spesimen beton kolom silinder (BKS) yang dilapisi oleh komposit hibrid laminat jute glass …
Analisis Kekuatan Tekan Struktur Beton Kolom Silinder Diperkuat Komposit Laminat Hibrid Jute E-glass Epoksi Eksperimental dan ANOVA
Tujuan dari penyelidikan ini ialah analisis kekuatan tekan struktur beton kolom silinder
(BKS) diperkuat oleh mateial komposit hibrid laminate jute e-glass epoksi (KHLJG) secara …
(BKS) diperkuat oleh mateial komposit hibrid laminate jute e-glass epoksi (KHLJG) secara …
Experimental study of jacket height and reinforcement effects on seismic retrofitting of concrete columns
This study evaluates the jacket height and reinforcement effects on reinforced concrete (RC)
square columns retrofitted with normal concrete. Five one-third scale columns with non …
square columns retrofitted with normal concrete. Five one-third scale columns with non …
Rehabilitation and strengthening techniques for reinforced concrete columns
Reinforced concrete (RC) columns are the primary load-bearing structural components in
the building which makes them most likely vulnerable to deterioration. Capacity deterioration …
the building which makes them most likely vulnerable to deterioration. Capacity deterioration …
Strengthening of concrete square column using FRP composites
A Manoj, D Sathyan - Journal of Physics: Conference Series, 2021 - iopscience.iop.org
Strength and energy absorption capacity are the important parameter for axially loaded
column. This paper investigates the strength of unconfined square concrete column and …
column. This paper investigates the strength of unconfined square concrete column and …
Compression behavior of cylinder reinforced with aramid fiber reinforced polymer
Reinforced Concrete (RC) is a wonderful conglomerate material by the help of which, a
structure or any structural element attains both compressive and tensile strength …
structure or any structural element attains both compressive and tensile strength …
[HTML][HTML] Influence of Cross-Section Shape and FRP Reinforcement Layout on Shear Capacity of Strengthened RC Beams
The evaluation of the shear capacity of an FRP-strengthened reinforced-concrete beam is
challenging due to the complex interaction between different contributions provided by the …
challenging due to the complex interaction between different contributions provided by the …
[PDF][PDF] Study on retrofitting of RC column using ferrocement full and strip wrap**
R Balamuralikrishnan, M Al Madhani… - Civil Engineering …, 2019 - core.ac.uk
Ferrocement is one of the cement-based composites used for retrofitting and rehabilitation
among many applications. Ferrocement is one of the reinforced concrete form with …
among many applications. Ferrocement is one of the reinforced concrete form with …
Enhancing load capacity of reinforced concrete columns using high strength concrete and fiber reinforcement
SS Ali, A Hassoon, HS Abbas… - Sustainable …, 2024 - sei.ardascience.com
Strengthening of structural elements is sometimes necessary for architectural purposes to
withstand additional loads without cross-section enlargement. This study evaluates the …
withstand additional loads without cross-section enlargement. This study evaluates the …