Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
[HTML][HTML] Influence of contamination distribution in characterizing the flashover phenomenon on outdoor insulator
The aim of this work is to model the influence of uneven contamination distribution under
various humidity on the pollution flashover voltage of 11 kV porcelain insulator disc. Four …
various humidity on the pollution flashover voltage of 11 kV porcelain insulator disc. Four …
[HTML][HTML] Investigation of high voltage polymeric insulators performance under wet pollution
In this paper, a unique approach based on electrical characteristics observed from
measurements of contaminated polymeric insulators was established to calculate the …
measurements of contaminated polymeric insulators was established to calculate the …
The Insulation Performance of Novel Refrigerant Gas as an Alternative to SF6 For Medium Voltage Switchgear
Gas-insulated systems are widely utilized in the electric power sector to transmit and
distribute electrical energy. Sulphur-hexafluoride (SF6) has dominated gas insulation in high …
distribute electrical energy. Sulphur-hexafluoride (SF6) has dominated gas insulation in high …
[PDF][PDF] Frequency response analysis for transformer tap changer damage detection
Frequency response analysis (FRA) method has been proven to detect the transformer
winding damage. However, there is no practical study which investigates the damages on …
winding damage. However, there is no practical study which investigates the damages on …
[PDF][PDF] Evaluation of mobile microwave electric field severity at Al-door residential complex in Iraq
In this paper, the electromagnetic radiation of the mobile microwave signals, propagated by
the mobile towers in Al-Door Residential Complex west of Iraq, is measured and evaluated …
the mobile towers in Al-Door Residential Complex west of Iraq, is measured and evaluated …
[HTML][HTML] Analysis of the Insulation Characteristics of Hexafluorobutene (C4H2F6) Gas and Mixture with CO2/N2 as an Alternative to SF6 for Medium-Voltage …
This paper investigates C4H2F6, a promising environmentally friendly insulating gas that
possesses high dielectric strength and a low global warming potential. The study focuses on …
possesses high dielectric strength and a low global warming potential. The study focuses on …
An alternative approaches to predict flashover voltage on polluted outdoor insulators using artificial intelligence techniques
This paper presents an alternative approach for predicting critical voltage of pollution
flashover by using Artificial Intelligence (AI) technique. Data from experimental works …
flashover by using Artificial Intelligence (AI) technique. Data from experimental works …
The Electric Field Characteristics in Clevis Type Polymer Insulators Affected by Size and Contact Angle of the Contaminants: Simulation Approach
Indonesia, as an archipelago and tropical country, results in a unique working environment
for polymer insulators. Then as discovered that insulators are aging in the coastal area more …
for polymer insulators. Then as discovered that insulators are aging in the coastal area more …
Artificial intelligence techniques for predicting the flashover voltage on polluted cup-pin insulators
In this paper, flashover characteristics of polluted cup-pin insulators have investigated by
means of laboratory test and a mathematical model. Data from experimental works …
means of laboratory test and a mathematical model. Data from experimental works …
Characterization of metamaterials
AP Franco, LA Espitia - Advanced Metamaterials for Engineers, 2023 - iopscience.iop.org
Abstract Characterization is a fundamental issue on metamaterials (MTM) science due to the
possibility of modulating properties as permittivity, permeability, and refraction index …
possibility of modulating properties as permittivity, permeability, and refraction index …