Shunt active power filter: Current status of control techniques and its integration to renewable energy sources

R Kumar, HO Bansal - Sustainable Cities and Society, 2018 - Elsevier
The renewable energy sources (RESs) are a viable alternative to fulfill the ever-rising
energy demand. The present power distribution system contains nonlinear loads that bring …

Operation of wind-turbine-driven DFIG systems under distorted grid voltage conditions: Analysis and experimental validations

H Xu, J Hu, Y He - IEEE Transactions on power electronics, 2011 - ieeexplore.ieee.org
This paper presents enhanced control strategies for doubly fed induction generator (DFIG)-
based wind power generation systems under distorted grid voltage conditions. The …

Doubly fed induction generator for wind energy conversion systems with integrated active filter capabilities

NKS Naidu, B Singh - IEEE transactions on industrial …, 2015 - ieeexplore.ieee.org
This paper deals with the operation of doubly fed induction generator (DFIG) with an
integrated active filter capabilities using grid-side converter (GSC). The main contribution of …

Integrated modeling and enhanced control of DFIG under unbalanced and distorted grid voltage conditions

H Xu, J Hu, Y He - IEEE Transactions on Energy Conversion, 2012 - ieeexplore.ieee.org
This paper focuses on the enhanced control and improved fault-ride-through capability of a
doubly fed induction generator (DFIG)-based wind turbine system under both unbalanced …

A proposal for a wind system equipped with a doubly fed induction generator using the Conservative Power Theory for active filtering of harmonics currents

RR Souza, AB Moreira, TAS Barros… - Electric Power Systems …, 2018 - Elsevier
This study describes a strategy that allows the addition of active filtering functionality to a
doubly fed induction generator (DFIG) wind power system. The active filtering is performed …

Direct power control of a DFIG-based WECS with active filter capabilities

E Tremblay, S Atayde, A Chandra - 2009 IEEE electrical power …, 2009 - ieeexplore.ieee.org
This paper presents an integrated control strategy for a DFIG-based wind energy conversion
system (WECS) with power quality enhancement capabilities. The proposed control scheme …

[HTML][HTML] Receiving-End Voltage Compensation Method with NPC-Inverter-Based Active Power Line Conditioner in Three-Phase Four-Wire Distribution Feeder

Y Sabi, H Yamada - Electricity, 2024 - mdpi.com
This study proposes a receiving-end voltage compensation method employing a phase-
specific reactive power control strategy with a neutral-point-clamped (NPC) inverter in a …

Stator harmonic current suppression for DFIG wind power system under distorted grid voltage

W Chen, J Xu, N Zhu, C Liu, M Chen… - 2012 3rd IEEE …, 2012 - ieeexplore.ieee.org
Effects of lower order harmonic grid voltage on the stator current of the Doubly Fed Induction
Generator (DFIG) are investigated. A stator harmonic current control method for DFIG wind …

A hybrid wind energy conversion system/active filter for non linear conditions

T Mesbahi, A Ouari, T Ghennam, EM Berkouk… - International Journal of …, 2016 - Springer
This paper presents the direct power control of a hybrid wind energy conversion
system/active filter for non linear condition. The rotor side converter controls the active and …

Design and control of wind integrated shunt active power filter to improve power quality

R Kumar, HO Bansal - 2018 IEEE 8th Power India International …, 2018 - ieeexplore.ieee.org
In this paper wind energy conservation system (WECS) with shunt active power filter (SAPF)
is proposed for harmonics elimination, power factor correction, reactive power compensation …