Shunt active power filter: Current status of control techniques and its integration to renewable energy sources
The renewable energy sources (RESs) are a viable alternative to fulfill the ever-rising
energy demand. The present power distribution system contains nonlinear loads that bring …
energy demand. The present power distribution system contains nonlinear loads that bring …
Operation of wind-turbine-driven DFIG systems under distorted grid voltage conditions: Analysis and experimental validations
This paper presents enhanced control strategies for doubly fed induction generator (DFIG)-
based wind power generation systems under distorted grid voltage conditions. The …
based wind power generation systems under distorted grid voltage conditions. The …
Doubly fed induction generator for wind energy conversion systems with integrated active filter capabilities
This paper deals with the operation of doubly fed induction generator (DFIG) with an
integrated active filter capabilities using grid-side converter (GSC). The main contribution of …
integrated active filter capabilities using grid-side converter (GSC). The main contribution of …
Integrated modeling and enhanced control of DFIG under unbalanced and distorted grid voltage conditions
This paper focuses on the enhanced control and improved fault-ride-through capability of a
doubly fed induction generator (DFIG)-based wind turbine system under both unbalanced …
doubly fed induction generator (DFIG)-based wind turbine system under both unbalanced …
A proposal for a wind system equipped with a doubly fed induction generator using the Conservative Power Theory for active filtering of harmonics currents
This study describes a strategy that allows the addition of active filtering functionality to a
doubly fed induction generator (DFIG) wind power system. The active filtering is performed …
doubly fed induction generator (DFIG) wind power system. The active filtering is performed …
Direct power control of a DFIG-based WECS with active filter capabilities
E Tremblay, S Atayde, A Chandra - 2009 IEEE electrical power …, 2009 - ieeexplore.ieee.org
This paper presents an integrated control strategy for a DFIG-based wind energy conversion
system (WECS) with power quality enhancement capabilities. The proposed control scheme …
system (WECS) with power quality enhancement capabilities. The proposed control scheme …
[HTML][HTML] Receiving-End Voltage Compensation Method with NPC-Inverter-Based Active Power Line Conditioner in Three-Phase Four-Wire Distribution Feeder
Y Sabi, H Yamada - Electricity, 2024 - mdpi.com
This study proposes a receiving-end voltage compensation method employing a phase-
specific reactive power control strategy with a neutral-point-clamped (NPC) inverter in a …
specific reactive power control strategy with a neutral-point-clamped (NPC) inverter in a …
Stator harmonic current suppression for DFIG wind power system under distorted grid voltage
Effects of lower order harmonic grid voltage on the stator current of the Doubly Fed Induction
Generator (DFIG) are investigated. A stator harmonic current control method for DFIG wind …
Generator (DFIG) are investigated. A stator harmonic current control method for DFIG wind …
A hybrid wind energy conversion system/active filter for non linear conditions
This paper presents the direct power control of a hybrid wind energy conversion
system/active filter for non linear condition. The rotor side converter controls the active and …
system/active filter for non linear condition. The rotor side converter controls the active and …
Design and control of wind integrated shunt active power filter to improve power quality
In this paper wind energy conservation system (WECS) with shunt active power filter (SAPF)
is proposed for harmonics elimination, power factor correction, reactive power compensation …
is proposed for harmonics elimination, power factor correction, reactive power compensation …