Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Advanced Monte Carlo simulations of emission tomography imaging systems with GATE
Built on top of the Geant4 toolkit, GATE is collaboratively developed for more than 15 years
to design Monte Carlo simulations of nuclear-based imaging systems. It is, in particular …
to design Monte Carlo simulations of nuclear-based imaging systems. It is, in particular …
Physics and technology of time-of-flight PET detectors
DR Schaart - Physics in Medicine & Biology, 2021 - iopscience.iop.org
The imaging performance of clinical positron emission tomography (PET) systems has
evolved impressively during the last∼ 15 years. A main driver of these improvements has …
evolved impressively during the last∼ 15 years. A main driver of these improvements has …
Green algorithms: quantifying the carbon footprint of computation
Climate change is profoundly affecting nearly all aspects of life on earth, including human
societies, economies, and health. Various human activities are responsible for significant …
societies, economies, and health. Various human activities are responsible for significant …
DeepPET: A deep encoder–decoder network for directly solving the PET image reconstruction inverse problem
The purpose of this research was to implement a deep learning network to overcome two of
the major bottlenecks in improved image reconstruction for clinical positron emission …
the major bottlenecks in improved image reconstruction for clinical positron emission …
A potential revolution in cancer treatment: A topical review of FLASH radiotherapy
FLASH radiotherapy (RT) is a novel technique in which the ultrahigh dose rate (UHDR)(≥
40 Gy/s) is delivered to the entire treatment volume. Recent outcomes of in vivo studies …
40 Gy/s) is delivered to the entire treatment volume. Recent outcomes of in vivo studies …
The OpenGATE ecosystem for Monte Carlo simulation in medical physics
This paper reviews the ecosystem of GATE, an open-source Monte Carlo toolkit for medical
physics. Based on the shoulders of Geant4, the principal modules (geometry, physics …
physics. Based on the shoulders of Geant4, the principal modules (geometry, physics …
A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications
In this paper, the authors' review the applicability of the open‐source GATE Monte Carlo
simulation platform based on the GEANT4 toolkit for radiation therapy and dosimetry …
simulation platform based on the GEANT4 toolkit for radiation therapy and dosimetry …
4D XCAT phantom for multimodality imaging research
Purpose: The authors develop the 4D extended cardiac‐torso (XCAT) phantom for
multimodality imaging research. Methods: Highly detailed whole‐body anatomies for the …
multimodality imaging research. Methods: Highly detailed whole‐body anatomies for the …
Nuclear medicine and artificial intelligence: best practices for evaluation (the RELAINCE guidelines)
An important need exists for strategies to perform rigorous objective clinical-task-based
evaluation of artificial intelligence (AI) algorithms for nuclear medicine. To address this need …
evaluation of artificial intelligence (AI) algorithms for nuclear medicine. To address this need …
A review on segmentation of positron emission tomography images
Abstract Positron Emission Tomography (PET), a non-invasive functional imaging method at
the molecular level, images the distribution of biologically targeted radiotracers with high …
the molecular level, images the distribution of biologically targeted radiotracers with high …