Power transmission lines: Worldwide research trends

F Alcayde-García, E Salmerón-Manzano, MA Montero… - Energies, 2022 - mdpi.com
The importance of the quality and continuity of electricity supply is increasingly evident given
the dependence of the world economy on its daily and instantaneous operation. In turn, the …

Incipient faults monitoring in underground medium voltage cables of distribution systems based on a two-step strategy

M Jannati, B Vahidi… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Incipient faults in underground cables are often resulted from electric stress and cable aging.
If such faults occur as current spikes in short periods, permanent faults may appear …

ADALINE (ADAptive Linear NEuron)-based coordinated control for wind power fluctuations smoothing with reduced BESS (battery energy storage system) capacity

M Jannati, SH Hosseinian, B Vahidi, G Li - Energy, 2016 - Elsevier
Most wind turbine generators installed in large wind farms are variable speed types which
operate at the maximum power point tracking mode in order to increase the power …

Synchrophasor-based intelligent autoreclosing scheme for series compensated transmission lines

S Gajare, AK Pradhan - IEEE Transactions on Power Delivery, 2016 - ieeexplore.ieee.org
In a transmission network, autoreclosing provides quick restoration of the line for transient
faults and improves system stability. Autoreclosing during permanent fault may damage …

An Adaline based arcing fault detection algorithm for single-pole autoreclosers

O Karacasu, MH Hocaoglu - Electric Power Systems Research, 2011 - Elsevier
In this paper, a new Adaline based adaptive single-pole autorecloser algorithm is proposed
to discriminate permanent and transient faults in HV transmission lines. The proposed …

[PDF][PDF] Fopid design for load-frequency control using genetic algorithm

N Bayati, A Dadkhah, B Vahidi, SHH Sadeghi - Sci. Int, 2015 - academia.edu
A fractional order PID (FOPID) for a load frequency control (LFC) is presented in a three-
area power system. FOPID controllers are designed the same way as PID controllers are …

An accurate technique for discrimination between transient and permanent faults in transmission networks

AR Adly, RA El-Sehiemy, AY Abdelaziz… - … power components and …, 2017 - Taylor & Francis
This paper presents an assessment study for adaptive single-pole automatic reclosure
(ASPAR) schemes to select correctly the best scheme at responsible indices. Suggested …

Mitigation of windfarm power fluctuation by adaptive linear neuron‐based power tracking method with flexible learning rate

M Jannati, SH Hosseinian, B Vahidi… - IET Renewable Power …, 2014 - Wiley Online Library
Most wind turbine generators installed in large windfarms are of variable speed types
operating at the maximum power point tracking mode to generate the maximum amount of …

Improving the stability of power transmission lines based on an adaptive single pole auto‐reclosure using a two‐step strategy

M Jannati, MY Nazari - IET Generation, Transmission & …, 2020 - Wiley Online Library
As more than 80% of single line to ground faults in power transmission lines (PTLs) are
transient, single pole auto‐reclosure (SPAR) is of considerable importance for increasing …

Hardware implementation of a real‐time adaptive single‐phase auto‐reclosure for power transmission lines

M Jannati, J Moshtagh - International Transactions on …, 2020 - Wiley Online Library
In order to distinguish permanent single line‐to‐ground faults from transient faults and
prevent reclosing in the case of a permanent fault occurrence, an adaptive algorithm is …