MRI‐related heating of implants and devices: a review

L Winter, F Seifert, L Zilberti, M Murbach… - Journal of Magnetic …, 2021 - Wiley Online Library
During an MRI scan, the radiofrequency field from the scanner's transmit coil, but also the
switched gradient fields, induce currents in any conductive object in the bore. This makes …

Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT

MJ Lee, S Kim, SA Lee, HT Song, YM Huh, DH Kim… - Radiographics, 2007 - pubs.rsna.org
At magnetic resonance (MR) imaging and multidetector computed tomography (CT), artifacts
arising from metallic orthopedic hardware are an obstacle to obtaining optimal images …

SEMAC: slice encoding for metal artifact correction in MRI

W Lu, KB Pauly, GE Gold, JM Pauly… - … in Medicine: An …, 2009 - Wiley Online Library
Magnetic resonance imaging (MRI) near metallic implants remains an unmet need because
of severe artifacts, which mainly stem from large metal‐induced field inhomogeneities. This …

PET/MR imaging: technical aspects and potential clinical applications

DA Torigian, H Zaidi, TC Kwee, B Saboury, JK Udupa… - Radiology, 2013 - pubs.rsna.org
Instruments that combine positron emission tomography (PET) and magnetic resonance
(MR) imaging have recently been assembled for use in humans, and may have diagnostic …

An outlook on future design of hybrid PET/MRI systems

H Zaidi, A Del Guerra - Medical physics, 2011 - Wiley Online Library
Early diagnosis and therapy increasingly operate at the cellular, molecular, or even at the
genetic level. As diagnostic techniques transition from the systems to the molecular level, the …

Complications of total hip arthroplasty: MR imaging—initial experience

LM White, JK Kim, M Mehta, N Merchant… - Radiology, 2000 - pubs.rsna.org
PURPOSE: To investigate the use of standard magnetic resonance (MR) imaging
sequences with simple parameter modifications for the detection and characterization of …

SQUID-detected magnetic resonance imaging in microtesla fields

J Clarke, M Hatridge, M Mößle - Annu. Rev. Biomed. Eng., 2007 - annualreviews.org
The use of very low noise magnetometers based on Superconducting QUantum Interference
Devices (SQUIDs) enables nuclear magnetic resonance (NMR) and magnetic resonance …

Pre-clinical PET/MR: technological advances and new perspectives in biomedical research

HF Wehrl, MS Judenhofer, S Wiehr… - European journal of …, 2009 - Springer
Abstract Introduction Combined PET/MRI allows for multi-parametric imaging and reveals
one or more functional processes simultaneously along with high-resolution morphology …

Effect of device configuration and patient's body composition on the RF heating and nonsusceptibility artifact of deep brain stimulation implants during MRI at 1.5 T and …

B Bhusal, BT Nguyen, PP Sanpitak, J Vu… - Journal of Magnetic …, 2021 - Wiley Online Library
Background Patients with deep brain stimulation (DBS) implants have limited access to MRI
due to safety concerns associated with RF‐induced heating. Currently, MRI in these patients …

Artifacts in magnetic resonance imaging and computed tomography caused by dental materials

T Klinke, A Daboul, J Maron, T Gredes, R Puls… - PLoS …, 2012 - journals.plos.org
Background Artifacts caused by dental restorations, such as dental crowns, dental fillings
and orthodontic appliances, are a common problem in MRI and CT scans of the head and …