ADALINE-network-based PLL for position sensorless interior permanent magnet synchronous motor drives

G Zhang, G Wang, D Xu, N Zhao - IEEE Transactions on Power …, 2015 - ieeexplore.ieee.org
To diminish the harmonic ripple in the rotor position estimation error for sensorless interior
permanent magnet synchronous motor (IPMSM) drives, an adaptive linear neural …

A review of single phase adaptive auto-reclosing schemes for EHV transmission lines

WA Khan, T Bi, K Jia - Protection and Control of Modern Power …, 2019 - ieeexplore.ieee.org
Statistics shows that transients produced by lightning or momentary links with external
objects, have produced more than 80% of faults in overhead lines. Reclosing of circuit …

A two-stage ADALINE for harmonics and interharmonics measurement

GW Chang, CI Chen, QW Liang - IEEE Transactions on …, 2009 - ieeexplore.ieee.org
Harmonics and interharmonics may introduce operational problems in electrical and
electronic equipment. Therefore, monitoring harmonics/interharmonics for improving the …

Real-time power system phasors and harmonics estimation using a new decoupled recursive-least-squares technique for DSP implementation

I Sadinezhad, VG Agelidis - IEEE Transactions on industrial …, 2012 - ieeexplore.ieee.org
This paper presents the mathematical basis to restructure the recursive-least-squares (RLS)
technique for real-time implementations on digital signal processors (DSPs). The proposed …

Improved Grey predictor rolling models for wind power prediction

THM El-Fouly, EF El-Saadany, MMA Salama - IET Generation, Transmission & …, 2007 - IET
A new technique for one step ahead average hourly wind speed forecasting and wind
turbines' output power prediction based on using the Grey predictor models is presented …

A data-driven hybrid methodology using randomized low-rank dmd approximation and flat-top fir filter for voltage fluctuations monitoring in grid-connected distributed …

N Mohan, SS Kumar, KP Soman, VG Sujadevi… - IEEE …, 2023 - ieeexplore.ieee.org
The voltage fluctuations are caused by variations in renewable energy source outputs,
increased usage of nonlinear loads, high reactive power consumption of loads, etc. This …

[HTML][HTML] Analyzing and mitigating the impacts of integrating fast-charging stations on the power quality in electric power distribution systems

SM Alshareef - Sustainability, 2022 - mdpi.com
The research presented in this paper focuses on the impacts of fast-charging stations on
three power quality phenomena, namely voltage magnitude variations, voltage unbalance …

Fast S-transform for time-varying voltage flicker analysis

W Yao, Q Tang, Z Teng, Y Gao… - IEEE Transactions on …, 2013 - ieeexplore.ieee.org
Voltage flicker analysis is one of the elementary tools of power quality assessment in power
systems. A new algorithm, fast S-transform (FST) is proposed and is used to analyze the time …

[HTML][HTML] A novel smart charging method to mitigate voltage fluctuation at fast charging stations

SM Alshareef - Energies, 2022 - mdpi.com
The research presented in this paper focuses on the impact of fast charging stations (FCSs)
on voltage quality. When the operation of FCSs causes a voltage fluctuation and light flicker …

Effective voltage flicker calculation based on multiresolution S-transform

N Eghtedarpour, E Farjah… - IEEE transactions on …, 2012 - ieeexplore.ieee.org
This paper introduces a new method for calculating the voltage flicker characteristics. A
voltage waveform envelope, which captures the main flicker characteristics, is obtained by …