A review of CMOS electrochemical readout interface designs for biomedical assays
SY Lu, SS Shan, TH Lu, YH Yeh, SC Kuo… - IEEE Sensors …, 2021 - ieeexplore.ieee.org
Electrochemical sensing has been widely applied to a variety of applications involving
disease diagnosis due to its ability to measure targets directly, fast response, and high …
disease diagnosis due to its ability to measure targets directly, fast response, and high …
Active CMOS sensor array for electrochemical biomolecular detection
Electrochemical sensing of biomolecules eliminates the need for the bulky and expensive
optical instrumentation required in traditional fluorescence-based sensing assays …
optical instrumentation required in traditional fluorescence-based sensing assays …
Chopper-stabilized bidirectional current acquisition circuits for electrochemical amperometric biosensors
Two low-noise bidirectional current acquisition circuits for interfacing with electrochemical
amperometric biosensor arrays are presented. The first design is a switched-capacitor …
amperometric biosensor arrays are presented. The first design is a switched-capacitor …
[KİTAP][B] Labs on chip: Principles, design and technology
E Iannone - 2018 - taylorfrancis.com
Labs on Chip: Principles, Design and Technology provides a complete reference for the
complex field of labs on chip in biotechnology. Merging three main areas—fluid dynamics …
complex field of labs on chip in biotechnology. Merging three main areas—fluid dynamics …
Simultaneous monitoring of anesthetics and therapeutic compounds with a portable multichannel potentiostat
As metabolic pathways are highly variable among different patients, then an accurate and
continuous monitoring of the personal response to drug treatments is essential especially …
continuous monitoring of the personal response to drug treatments is essential especially …
Low power integrated potentiostat design for μ electrodes with improved accuracy
M Duwe, T Chen - 2011 IEEE 54th International Midwest …, 2011 - ieeexplore.ieee.org
μelectrodes measuring smaller than 10 μm in size are seen as necessary for improving
spatial resolution for detecting bio-activities at the cellular level. Improving measurement …
spatial resolution for detecting bio-activities at the cellular level. Improving measurement …
CMOS potentiostat for chemical sensing applications
We demonstrate a CMOS (complementary metal oxide semiconductor) potentiostat chip
fabricated in a standard 0.5 μm CMOS process to perform electrochemical analysis via cyclic …
fabricated in a standard 0.5 μm CMOS process to perform electrochemical analysis via cyclic …
CMOS-based on-chip electrochemical sensor
T Luo, H Wang, H Song… - 2014 IEEE Biomedical …, 2014 - ieeexplore.ieee.org
We describe an integrated CMOS electrochemical sensor with on-chip electrodes and
packaging. The CMOS chip was fabricated in a standard 0.5 µm CMOS process, and it …
packaging. The CMOS chip was fabricated in a standard 0.5 µm CMOS process, and it …
High accuracy and sensitivity differential potentiostat with amplifier-based error cancellation feedback loop
E Ghodsevali, B Gosselin… - … Circuits and Systems …, 2015 - ieeexplore.ieee.org
We present a low-current, high sensitivity and high linearity biosensor dedicated to
neurotransmitter detection. The design is based on a fully-differential amplifier for enhanced …
neurotransmitter detection. The design is based on a fully-differential amplifier for enhanced …
Biochemical sensor interface circuits with differential difference amplifier
SI Lim, IS Choi, HH Lee - 2012 IEEE Asia Pacific Conference …, 2012 - ieeexplore.ieee.org
A simple three-electrode CMOS interface system for electrochemical sensor is described. To
maintain a constant potential between the reference electrode (RE) and working electrode …
maintain a constant potential between the reference electrode (RE) and working electrode …