Optimization of miniature Joule-Thomson cryocooler with non-isometric recuperator on transient characteristics
H Chen, C Wei, W Ding, Y Liu - Energy, 2023 - Elsevier
A novel JT cryocooler transient performance evaluation criteria parameter, transient
evaluation coefficient ξ, is proposed. It includes the cool-down time, refrigerant, and material …
evaluation coefficient ξ, is proposed. It includes the cool-down time, refrigerant, and material …
Experimental and numerical investigation of open-cycle miniature Joule-Thomson cryocooler for working temperatures 100 K to 150 K with single component coolants
A Shapiro, M Greenberg, A Parahovnik - Cryogenics, 2022 - Elsevier
Krypton and R14 (ie single component gasses) were studied as potential coolants for an
open cycle miniature Joule-Thomson cryocooler. Cooling experiments were performed at …
open cycle miniature Joule-Thomson cryocooler. Cooling experiments were performed at …
Cryogenic distribution system design for cryomodules and cavities test in HIAF project
W **an **, C Shu **, W Jun, Z Peng… - Journal of Nuclear …, 2024 - Taylor & Francis
High-intensity heavy-ion accelerator facility (HIAF) is an accelerator-driven high-current
heavy ion facility, currently under construction in Guangdong, China. The proton linear …
heavy ion facility, currently under construction in Guangdong, China. The proton linear …
Heat transfer analysis for finned tube heat exchangers
This present paper fulfils a parametric study about heat exchangers with extended surface.
These finned tube heat exchangers commonly used in industry, household and automotive …
These finned tube heat exchangers commonly used in industry, household and automotive …
HEAT TRANSFER IN THE CHANNELS OF THE HEAT EXCHANGER INTENDED FOR THE RECOVERY VENTILATION SYSTEM OF THE ROOM
BI Basok, TG Beljaeva, DB Davydenko - Thermophysics and Thermal …, 2024 - ihe.nas.gov.ua
Air exchange, or ventilation, systems are created to ensure comfortable conditions in rooms
in terms of temperature, humidity, and oxygen content in the air. In energy-efficient buildings …
in terms of temperature, humidity, and oxygen content in the air. In energy-efficient buildings …
Numerical study of the effect of the helium-based multi-component gas mixture on the internal purifier
G Feng, Q Jia, L Gong, M Zhang, P Xu… - IOP Conference …, 2020 - iopscience.iop.org
The performance of the internal purifier has a direct impact on the liquefaction capacity of the
helium liquefier. With increasing impurity level in helium, liquefaction capacity of the helium …
helium liquefier. With increasing impurity level in helium, liquefaction capacity of the helium …