Advanced methods of plant disease detection. A review

F Martinelli, R Scalenghe, S Davino, S Panno… - Agronomy for …, 2015 - Springer
Plant diseases are responsible for major economic losses in the agricultural industry
worldwide. Monitoring plant health and detecting pathogen early are essential to reduce …

Clinical application of volatile organic compound analysis for detecting infectious diseases

S Sethi, R Nanda, T Chakraborty - Clinical microbiology reviews, 2013 - Am Soc Microbiol
This review article introduces the significance of testing of volatile organic compounds
(VOCs) in clinical samples and summarizes important features of some of the technologies …

Breath acetone monitoring by portable Si: WO3 gas sensors

M Righettoni, A Tricoli, S Gass, A Schmid, A Amann… - Analytica chimica …, 2012 - Elsevier
Breath analysis has the potential for early stage detection and monitoring of illnesses to
drastically reduce the corresponding medical diagnostic costs and improve the quality of life …

Review of applications of high-field asymmetric waveform ion mobility spectrometry (FAIMS) and differential mobility spectrometry (DMS)

BM Kolakowski, Z Mester - Analyst, 2007 - pubs.rsc.org
High-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) and Differential Mobility
Spectrometry (DMS) harness differences in ion mobility in low and high electric fields to …

Breathborne biomarkers and the human volatilome

J Beauchamp, C Davis, J Pleil - 2020 - books.google.com
Breathborne biomarkers carry information on the state of human health, and their role in
aiding clinical diagnosis or in therapeutic monitoring has become increasingly important as …

Review on ion mobility spectrometry. Part 2: hyphenated methods and effects of experimental parameters

R Cumeras, E Figueras, CE Davis, JI Baumbach… - Analyst, 2015 - pubs.rsc.org
Ion Mobility Spectrometry (IMS) is a widely used and 'well-known'technique of ion separation
in the gaseous phase based on the differences of ion mobilities under an electric field. This …

Ethanol sensor using gadolinia-doped ceria solid electrolyte and double perovskite structure sensing material

T Liu, T Wang, H Li, J Su, X Hao, F Liu, F Liu… - Sensors and Actuators B …, 2021 - Elsevier
Mixed potential gadolinia-doped ceria (GDC)-based gas sensors using a double perovskite
composite oxide (Sr 2 NiMoO 6) were fabricated to detect ethanol. The influence of the …

Ion mobility in clinical analysis: current progress and future perspectives

CD Chouinard, MS Wei, CR Beekman… - Clinical …, 2016 - academic.oup.com
BACKGROUND Ion mobility spectrometry (IMS) is a rapid separation tool that can be
coupled with several sampling/ionization methods, other separation techniques (eg …

Ion mobility spectrometry for microbial volatile organic compounds: a new identification tool for human pathogenic bacteria

M Jünger, W Vautz, M Kuhns, L Hofmann… - Applied microbiology …, 2012 - Springer
Presently, 2 to 4 days elapse between sampling at infection suspicion and result of microbial
diagnostics. This delay for the identification of pathogens causes quite often a late and/or …

Ion mobility spectrometry detection for gas chromatography

AB Kanu, HH Hill Jr - Journal of Chromatography A, 2008 - Elsevier
The hyphenated analytical method in which ion mobility spectrometry (IMS) is coupled to
gas chromatography (GC) provides a versatile alternative for the sensitive and selective …