Dynamic thermal environment management technologies for data center: A review
Y Du, Z Zhou, X Yang, X Yang, C Wang, J Liu… - … and Sustainable Energy …, 2023 - Elsevier
The energy demand of the data center (DC) industry has accounted for 2% of the total global
energy consumption, and its operating power consumption has reached 50 times that of the …
energy consumption, and its operating power consumption has reached 50 times that of the …
Model-based control strategy with linear parameter-varying state-space model for rack-based cooling data centers
W Deng, J Wang, C Yue, Y Guo, Q Zhang - Energy and Buildings, 2024 - Elsevier
Cooling system energy consumption occupies approximately 40% of the total energy
consumption in data centers, and efficient control is crucial for improving cooling efficiency …
consumption in data centers, and efficient control is crucial for improving cooling efficiency …
Energy, exergy and computing efficiency based data center workload and cooling management
The rapidly rising computing workloads in data centers (DCs) have necessitated new
approaches to ensure effective performance and resilience that minimize the associated …
approaches to ensure effective performance and resilience that minimize the associated …
Waste heat recovery in a data center with an adsorption chiller: Technical and economic analysis
Computing load of data centers and high-performance clusters have increased significantly
over the past decade, resulting in higher energy consumption and a larger carbon footprint …
over the past decade, resulting in higher energy consumption and a larger carbon footprint …
A gray-box model for real-time transient temperature predictions in data centers
S Asgari, SM MirhoseiniNejad… - Applied Thermal …, 2021 - Elsevier
In response to the need to improve the energy efficiency of data centers (DCs), system
designers now incorporate solutions such as continuous performance monitoring …
designers now incorporate solutions such as continuous performance monitoring …
Dynamic performance analysis and thermal modelling of a novel two-phase spray cooled rack system for data center cooling
Cooling systems in information technology (IT) equipment account for the greatest share of
direct energy consumption in data centers. Conventional air-cooling schemes are thermally …
direct energy consumption in data centers. Conventional air-cooling schemes are thermally …
Joint data center cooling and workload management: A thermal-aware approach
SM MirhoseiniNejad, H Moazamigoodarzi… - Future Generation …, 2020 - Elsevier
Abstract Information technology (IT) equipment and cooling infrastructure are key
contributors to the total energy expenditure in a data center. There is typically significant …
contributors to the total energy expenditure in a data center. There is typically significant …
Influence of cooling architecture on data center power consumption
Almost thirty percent of the power consumed by data centers (DCs) is attributable to the
cooling of IT equipment (ITE). There are opportunities to reduce a DC's energy budget by …
cooling of IT equipment (ITE). There are opportunities to reduce a DC's energy budget by …
Modeling temperature distribution and power consumption in IT server enclosures with row-based cooling architectures
Traditional data center cooling methods cannot yet control cooling airflows and
temperatures on demand, creating an intrinsic inefficiency. A recent solution places row …
temperatures on demand, creating an intrinsic inefficiency. A recent solution places row …
Hybrid surrogate model for online temperature and pressure predictions in data centers
The increase in cloud computing and big data storage has led to significant growth in data
center (DC) infrastructure that is now estimated to consume more than 1.5% of the world's …
center (DC) infrastructure that is now estimated to consume more than 1.5% of the world's …