Applications of dielectric spectroscopy in time and frequency domain for HV power equipment

WS Zaengl - IEEE Electrical Insulation Magazine, 2003 - ieeexplore.ieee.org
Applications of dielectric spectroscopy in time and frequency domain for HV power equipment
Page 1 Applications of Dielectric Spectroscopy in Time and Frequency Domain for HV Power …

[PDF][PDF] Condition monitoring of power transformers-bibliography survey

J Singh, YR Sood, RK Jarial - IEEE Electrical Insulation Magazine, 2008 - academia.edu
Introduction ower transformers are one of the most expensive elements in a power system,
and their failure is a very costly event. Power transformers are mainly involved in energy …

Quantitative analysis ageing status of natural ester-paper insulation and mineral oil-paper insulation by polarization/depolarization current

J Hao, R Liao, G Chen, Z Ma… - IEEE Transactions on …, 2012 - ieeexplore.ieee.org
Polarization and Depolarization Current (PDC) technique is an effective tool to assess the
condition of oil-paper insulation system in power transformers. So far the PDC behaviors of …

[책][B] Hochspannungstechnik: Grundlagen—Technologie—Anwendungen

A Küchler - 2009 - Springer
Nachdem in den vorstehenden Kapiteln die Grundlagen und die Technologien der
Hochspannungstechnik beschrieben wurden, sollen beispielhaft auch typische …

Influence of natural ester on frequency dielectric response of impregnated insulation pressboard

J Hao, R Liao, Z Ma, L Yang - IET Science, Measurement & Technology, 2012 - IET
It is important to investigate the dielectric behaviour of natural ester-paper insulation, as the
number of transformers choosing natural ester as their insulation oil is increasing. A …

PDC measurement evaluation on oil-pressboard samples

AA Shayegani, O Hassan, H Borsi… - Proceedings of the …, 2004 - ieeexplore.ieee.org
In this paper the measuring results of polarization and depolarization currents (PDC) on oil-
pressboard samples will be presented. The measurements were carried out under different …

Noninvasive ageing assessment by means of polarization and depolarization currents analysis and its correlation with moisture content for power transformer life …

HAP Silva, W Bassi, ACT Diogo - 2004 IEEE/PES Transmision …, 2004 - ieeexplore.ieee.org
This paper presents the Brazilian experience on the application of a noninvasive technique
based on the dielectric response using the polarization and depolarization currents analysis …

Independent effects of aged oil and aged paper on moisture evaluation of power transformers

R Liao, Y Lin, Y Zhang, H **a - Electric Power Components and …, 2016 - Taylor & Francis
Estimating the moisture content of insulation paper is important in transformer condition
evaluation, the results of which are affected by thermal aging. This study investigates the …

Time domain spectroscopy measurements for the insulation diagnosis of a current transformer

A Kumar, SM Mahajan - IEEE Transactions on Dielectrics and …, 2011 - ieeexplore.ieee.org
There is a growing need for accurate but nonintrusive insulation diagnostic techniques and
better maintenance tools to assay the internal condition of transformers. Classical diagnostic …

Correlation between time and frequency domain measurements for the insulation diagnosis of current transformers

A Kumar, SM Mahajan - North American Power Symposium …, 2010 - ieeexplore.ieee.org
Transformer maintenance has evolved over the past few decades from an item of periodic
expenditure to a strategic planning tool in the management of transmission and distribution …