Proton response and neutron spectrum unfolding by solution-grown trans-stilbene scintillator

ND Quang, HJ Kim, S Kim, S Kang, PQ Vuong… - Scientific Reports, 2025 - nature.com
This paper reports the proton response function for solution-grown trans-stilbene scintillator
from 1 to 25 MeVee and its application for unfolding neutron spectra of Cf-252 and AmBe …

Characterization of the Multi-Blade 10B-based detector at the CRISP reflectometer at ISIS for neutron reflectometry at ESS

F Piscitelli, G Mauri, F Messi… - Journal of …, 2018 - iopscience.iop.org
Abstract The Multi-Blade is a Boron-10-based gaseous thermal neutron detector developed
to face the challenge arising in neutron reflectometry at neutron sources. Neutron …

Fast neutron sensitivity of neutron detectors based on boron-10 converter layers

G Mauri, F Messi, K Kanaki, R Hall-Wilton… - Journal of …, 2018 - iopscience.iop.org
In the last few years many detector technologies for thermal neutron detection have been
developed in order to face the shortage of 3 He, which is now much less available and more …

Verification of He-3 proportional counters' fast neutron sensitivity through a comparison with He-4 detectors-He-3 and He-4 proportional counters' fast neutron …

F Piscitelli, G Mauri, A Laloni… - The European Physical …, 2020 - epjplus.epj.org
In the field of neutron scattering science, a large variety of instruments require detectors for
thermal and cold neutrons. Helium-3 has been one of the main actors in thermal and cold …

The Multi-Blade Boron-10-based neutron detector performance using a focusing reflectometer

G Mauri, I Apostolidis, MJ Christensen… - Journal of …, 2020 - iopscience.iop.org
Abstract The Multi-Blade is a Boron-10-based neutron detector designed for neutron
reflectometers and developed for the two instruments (Estia and FREIA) planned for the …

Fast neutron sensitivity for 3He detectors and comparison with Boron-10 based neutron detectors

G Mauri, F Messi, K Kanaki, R Hall-Wilton… - EPJ Techniques and …, 2019 - epjti.epj.org
The 3 He-based neutron detectors are no longer the default solution for neutron scattering
applications. Both the inability of fulfilling the requirements in performance, needed for the …

Software-based data acquisition and processing for neutron detectors at European Spallation Source—early experience from four detector designs

MJ Christensen, M Shetty, J Nilsson… - Journal of …, 2018 - iopscience.iop.org
Abstract European Spallation Source (ESS) will deliver neutrons at high flux for use in
diverse neutron scattering techniques. The neutron source facility and the scientific …

[HTML][HTML] Evaluation of the in-situ performance of neutron detectors based on EJ-426 scintillator screens for spent fuel characterization

H Perrey, L Ros, M Elfman, U Bäckström… - Nuclear Instruments and …, 2021 - Elsevier
The reliable detection of neutrons in a harsh gamma-ray environment is an important aspect
of establishing non-destructive methods for the characterization of spent nuclear fuel. In this …

Vanadium-based neutron beam monitor

V Maulerova, K Kanaki, PM Kadletz, R Woracek… - … Review Accelerators and …, 2020 - APS
A prototype quasiparasitic thermal neutron beam monitor based on isotropic neutron
scattering from a thin natural vanadium foil and standard He 3 proportional counters is …

Development and characterization of detectors for large area application in neutron scattering and small area application in neutron reflectometry

G Mauri - arxiv preprint arxiv:1905.12311, 2019 - arxiv.org
Neutron scattering techniques offer a unique combination of structural and the dynamic