Interoperability performance assessment of multivendor IEC61850 process bus

X Chen, H Guo, P Crossley - IEEE Transactions on Power …, 2015 - ieeexplore.ieee.org
Substations are increasingly reliant on devices compatible with IEC61850 standards.
However, the conformity of a device with the standards does not necessarily guarantee …

Distributed protection for smart substations based on multiple overlap** units

J He, Z Wang, Q Zhang, L Liu, D Zhang… - CSEE Journal of …, 2016 - ieeexplore.ieee.org
Taking advantage of the information sharing mechanism in smart substations, a distributed
protection based on multiple overlap** units is introduced in this paper. The area division …

Analysis of GOOSE message and the engineering application for GOOSE message in the intelligent substation

S Wang, F Yang, X Yan, T Liu - The Journal of Engineering, 2020 - Wiley Online Library
Generic Object Oriented Substation Event (GOOSE) message reflects the transmission of
information between many intelligent electronic devices, which is more reliable as original …

[PDF][PDF] IEC 61850 standard-based protection of the coupling point between a wind farm and the power grid

S Nomandela, M Ratshitanga… - Cape Peninsula University …, 2021 - researchgate.net
Power system aims to continuously supply power to customers even at very high demand.
The high energy demand causes a decrease in voltages at the substations and this may …

Digital substation backup protection using a multi-agent system approach

J He, T Yip, Y Huang, Z Wang, L Liu - 2016 - IET
Traditionally, differential protections are used in a substation to protect important plants such
as busbars and transformers. They are unit protection schemes which provide good …

Assessments and comparisons of ieds functionality and performance for both HSR and PRP configurations under laboratory setup and tests

L Xu, H Li, P Mohapatra - 15th International Conference on …, 2020 - ieeexplore.ieee.org
Driven by interoperability among multiple vendors equipment, Scottish Power Energy
Networks (SPENs) has deployed a full digital substation architecture and real digital …

Enhancement of IEC 61850 AS using Vendor-Natural system tool

M Mekkanen, R Virrankoski… - 2014 IEEE 27th …, 2014 - ieeexplore.ieee.org
The wide acceptance of the IEC61850 standard had been raised it to the focusing research
interesting area both from the academic and industry sides. This paper describes the …

[PDF][PDF] IEC 61850-standardin soveltaminen sulautetulla Linux-järjestelmällä

A Lemmetyinen - 2015 - osuva.uwasa.fi
IEC 61850-standardi määrittelee nykypäivän tietoliikenneyhteyskäytännön, jota sovelletaan
monesssa ympäristössä sähkötekniikan alueella. Standardin viimeisimmät versiot kattavat …

[BOOK][B] Performance Analysis of IEC 61850 Process Bus and Interoperability Test among Multi-Vendor System

X Chen - 2016 - search.proquest.com
IEC 61850 standards are the global standard for communication in substations. It isgaining
popularity in power substation automation and will dominate the futuresubstation automation …

[BOOK][B] Assessment of Impact of Substation Data Communication Networks on Protection and Control Functionality and Performance

L Xu - 2019 - search.proquest.com
Power substations are enablers for the electricity network power flow to be controlled and
directed safely and securely from generation to demand. To support the UK government …