Variable switching frequency techniques for power converters: Review and future trends
Variable-frequency (VF) techniques have been widely applied in the fields of power
electronics and motor drives. Based on the categories of frequency variables, the VF …
electronics and motor drives. Based on the categories of frequency variables, the VF …
A 2-kW single-phase seven-level flying capacitor multilevel inverter with an active energy buffer
High-efficiency and compact single-phase inverters are desirable in many applications such
as solar energy harvesting and electric vehicle chargers. This paper presents a 2-kW, 60-Hz …
as solar energy harvesting and electric vehicle chargers. This paper presents a 2-kW, 60-Hz …
Opening the box: Survey of high power density inverter techniques from the little box challenge
KA Kim, YC Liu, MC Chen… - CPSS Transactions on …, 2017 - ieeexplore.ieee.org
The Little Box Challenge (LBC) was a competition sponsored by Google and the IEEE
Power Electronics Society in 2014-2015, where participants were challenged to design a …
Power Electronics Society in 2014-2015, where participants were challenged to design a …
Design for reliability of power electronic systems
Power density, efficiency, cost, and reliability are the major challenges when designing a
power electronic system. Latest advancements in power semiconductor devices (eg, silicon …
power electronic system. Latest advancements in power semiconductor devices (eg, silicon …
A 98.3% efficient GaN isolated bidirectional DC–DC converter for DC microgrid energy storage system applications
This paper presents a novel 400 to 12 V isolated bidirectional dc-dc converter based on a
phase-shift-controlled-modified dual-active-bridge power stage. The proposed converter …
phase-shift-controlled-modified dual-active-bridge power stage. The proposed converter …
99.1% efficient 10 kV SiC-based medium-voltage ZVS bidirectional single-phase PFC AC/DC stage
Due to their extremely high energy demand, data centers are directly supplied from a
medium-voltage (MV) grid. However, a significant part of this energy is dissipated in the …
medium-voltage (MV) grid. However, a significant part of this energy is dissipated in the …
An analytical method to evaluate and design hybrid switched-capacitor and multilevel converters
This paper investigates the use of multilevel conversion in dc-dc applications that require a
large voltage conversion ratio. A quantitative method that can serve as a guide to compare …
large voltage conversion ratio. A quantitative method that can serve as a guide to compare …
On the Origin of the -Losses in Soft-Switching GaN-on-Si Power HEMTs
M Guacci, M Heller, D Neumayr, D Bortis… - IEEE Journal of …, 2018 - ieeexplore.ieee.org
The unprecedented performance potential of gallium nitride-on-silicon (GaN-on-Si) high
electron mobility transistors (HEMTs) is seen as the key enabler for the design of power …
electron mobility transistors (HEMTs) is seen as the key enabler for the design of power …
Accurate transient calorimetric measurement of soft-switching losses of 10-kV SiC MOSFETs and diodes
The characterization of soft-switching losses (SSL) of modern high-voltage SiC MOSFETS is
a difficult but necessary task in order to provide a sound basis for the accurate modeling of …
a difficult but necessary task in order to provide a sound basis for the accurate modeling of …
The essence of the little box challenge-part A: Key design challenges & solutions
In order to expedite the development of power electronic systems towards higher power
density and efficiency at a lower cost of implementation, Google and IEEE initiated the …
density and efficiency at a lower cost of implementation, Google and IEEE initiated the …