A review on the finite element simulation of fretting wear and corrosion in the taper junction of hip replacement implants
Taperosis/trunnionosis is a scientific term for describing tribocorrosion (fretting corrosion) at
the head-neck taper junction of hip implants where two contacting surfaces are undergone …
the head-neck taper junction of hip implants where two contacting surfaces are undergone …
An adaptive finite element simulation of fretting wear damage at the head-neck taper junction of total hip replacement: The role of taper angle mismatch
An adaptive finite element simulation was developed to predict fretting wear in a head-neck
taper junction of hip joint implant through a two dimensional (2D) model and based on the …
taper junction of hip joint implant through a two dimensional (2D) model and based on the …
A finite element study on the mechanical response of the head-neck interface of hip implants under realistic forces and moments of daily activities: Part 1, level walking
This paper investigates the mechanical response of a modular head-neck interface of hip
joint implants under realistic loads of level walking. The realistic loads of the walking activity …
joint implants under realistic loads of level walking. The realistic loads of the walking activity …
[HTML][HTML] The influence of assembly force on the material loss at the metallic head-neck junction of hip implants subjected to cyclic fretting wear
The impaction force required to assemble the head and stem components of hip implants is
proven to play a major role in the mechanics of the taper junction. However, it is not clear if …
proven to play a major role in the mechanics of the taper junction. However, it is not clear if …
Taper fretting behavior of PEEK artificial hip joint
H Xu, D Zhang, K Chen, T Zhang - Tribology International, 2019 - Elsevier
To study the fretting tribological behavior of a PEEK hip prosthesis, Ti6Al4V was used as the
stem taper material, PEEK was used as the head material, and CoCrMo was used as the …
stem taper material, PEEK was used as the head material, and CoCrMo was used as the …
A finite element study on the mechanical response of the head-neck interface of hip implants under realistic forces and moments of daily activities: Part 2
A finite element model was developed to investigate the effect of loading regimes caused by
various daily activities on the mechanical behaviour of the head-neck taper junction in …
various daily activities on the mechanical behaviour of the head-neck taper junction in …
In vivo damage of the head-neck junction in hard-on-hard total hip replacements: effect of femoral head size, metal combination, and 12/14 taper design
M Baleani, P Erani, B Bordini, F Zuccheri, MK Mąkosa… - Materials, 2017 - mdpi.com
Recently, concerns have been raised about the potential effect of head-neck junction
damage products at the local and systemic levels. Factors that may affect this damage …
damage products at the local and systemic levels. Factors that may affect this damage …
Mechanism of fretting corrosion at the modular taper interface of hip prosthesis
AO Oladokun - 2017 - etheses.whiterose.ac.uk
Modularity of total hip arthroplasty (THA) has been linked to various forms of adverse local
tissue reaction (ALTR). ALTR is often a result of metallic particles and ions released from …
tissue reaction (ALTR). ALTR is often a result of metallic particles and ions released from …
Experimental evaluation of the primary fixation stability of uncemented ceramic hip resurfacing implants
D Vogel, P Henke, A Haenel, J Mokros… - Proceedings of the …, 2022 - journals.sagepub.com
Hip resurfacing arthroplasty is associated with increased frictional moments compared to
standard heads owing to their large diameter. High frictional moments may harbor the risk of …
standard heads owing to their large diameter. High frictional moments may harbor the risk of …
Micromotion analysis of the head-neck interface of a PEEK artificial hip prosthesis
PEEK has been gradually recommended in recent years as a metal substitute for artificial
joint replacement. However, the risk of fretting of the PEEK artificial hip prosthesis in the …
joint replacement. However, the risk of fretting of the PEEK artificial hip prosthesis in the …