[HTML][HTML] Effect of indoor climatic conditions on the risk of water vapor condensation and mould growth

B Orlik-Kożdoń - Journal of Building Engineering, 2024 - Elsevier
The article presents a new approach to determining the risk of mold growth in buildings. To
assess this phenomenon, we use the so-called limit temperature factor f Rsi calculated …

Combined heat, air, moisture modelling: a look back, how, of help?

HLSC Hens - Building and Environment, 2015 - Elsevier
Trials to model combined heat, air, moisture transfer in and through building assemblies
started in the 1930-ties, when the first methodologies surfaced that coupled steady state …

A probabilistic-based methodology for predicting mould growth in façade constructions

K Gradeci, N Labonnote, B Time, J Köhler - Building and Environment, 2018 - Elsevier
Predicting mould growth on façade constructions during design is important for preventing
financial loss, and ensuring a healthy and comfortable indoor environment. Uncertainties in …

Indoor humidity loads and moisture production in lightweight timber-frame detached houses

T Kalamees, J Vinha, J Kurnitski - Journal of Building …, 2006 - journals.sagepub.com
In this study, the indoor humidity loads in 101 lightweight timber-frame detached houses
occupied by single families have been measured and analyzed. The temperature and …

[PDF][PDF] ASHRAE standard 160 P-Criteria for moisture control design analysis in buildings

A TenWolde - ASHRAE transactions, 2008 - fpl.fs.usda.gov
In 1996, ASHRAE formed a new Standard Project Committee, ASHRAE 160P, to develop a
standardfor moisture control in buildings. The draft standard __" Criteria for Mois ture Control …

Selection of moisture reference year for freeze-thaw damage assessment of historic masonry walls under future climate: A simulation-based approach

S Sahyoun, H Ge, MA Lacasse - Building and Environment, 2024 - Elsevier
Today, there is an increased research effort on improving energy efficiency in heritage
buildings through retrofit measures. Hygrothermal simulations tools are often used to assess …

Hygrothermal modeling of aerated concrete wall and comparison with field experiment

F Tariku, MK Kumaran - Research in building physics and building …, 2020 - taylorfrancis.com
A two-dimensional heat, air and moisture transport model called hyglRC is adapted to
simulate a well-documented field exposure of an aerated concrete wall section. Difficulties …

[PDF][PDF] A systematic method for hygrothermal analysis of building constructions using computer models

S Geving - Proceedings of the building simulation, 1997 - Citeseer
Knowledge of the expected longfterm performance of building envelopes subjected to
simultaneous heat and moisture transport is critical during the design stage. The last few …

What are the hygrothermal consequences of applying exterior air barriers in timber frame construction in Europe?

J Langmans, S Roels - Journal of Building Performance Simulation, 2015 - Taylor & Francis
Moisture-induced damage is one of the major causes of degradations and reduced thermal
performance in wood frame buildings. It is therefore crucial to incorporate the hygrothermal …

[KNIHA][B] Hygrothermal criteria for design and simulation of buildings

T Kalamees - 2006 - digikogu.taltech.ee
This study determined indoor and outdoor boundary conditions as design values for