Biomechanical behaviours of the bone–implant interface: a review

X Gao, M Fraulob, G Haïat - Journal of The Royal …, 2019‏ - royalsocietypublishing.org
In recent decades, cementless implants have been widely used in clinical practice to replace
missing organs, to replace damaged or missing bone tissue or to restore joint functionality …

Biomechanical properties of artificial bones made by Sawbones: A review

R Zdero, P Brzozowski, EH Schemitsch - Medical Engineering & Physics, 2023‏ - Elsevier
Biomedical engineers and physicists frequently use human or animal bone for orthopaedic
biomechanics research because they are excellent approximations of living bone. But, there …

Design and manufacture of customized dental implants by using reverse engineering and selective laser melting technology

J Chen, Z Zhang, X Chen, C Zhang, G Zhang… - The Journal of prosthetic …, 2014‏ - Elsevier
Statement of problem Recently a new therapeutic concept of patient-specific implant
dentistry has been advanced based on computer-aided design/computer-aided …

Comparison of proximal humeral bone stresses between stemless, short stem, and standard stem length: a finite element analysis

N Razfar, JM Reeves, DG Langohr, R Willing… - Journal of shoulder and …, 2016‏ - Elsevier
Background The stem lengths of humeral components used in shoulder arthroplasty vary;
however, the literature on these devices is limited. This finite element study investigates the …

Investigating the impact of diameters and thread designs on the Biomechanics of short implants placed in D4 bone: a 3D finite element analysis

AR Alqahtani, SR Desai, JR Patel, NR Alqhtani… - BMC Oral Health, 2023‏ - Springer
Background Dental implants emerge as a dependable and efficacious alternative for
patients experiencing partial or complete tooth loss. The stability of these implants is …

The influence of custom-milled framework design for an implant-supported full-arch fixed dental prosthesis: 3D-FEA sudy

JPM Tribst, AMO Dal Piva, R Lo Giudice… - International Journal of …, 2020‏ - mdpi.com
The current study aimed to evaluate the mechanical behavior of two different maxillary
prosthetic rehabilitations according to the framework design using the Finite Element …

Intrinsic osteoinductivity of porous titanium scaffold for bone tissue engineering

M Tamaddon, S Samizadeh, L Wang… - International journal …, 2017‏ - Wiley Online Library
Large bone defects and nonunions are serious complications that are caused by extensive
trauma or tumour. As traditional therapies fail to repair these critical‐sized defects, tissue …

Topological optimization in hip prosthesis design

M Fraldi, L Esposito, G Perrella, A Cutolo… - … and modeling in …, 2010‏ - Springer
With particular interest on total hip arthroplasty (THA), optimization of orthopedic prostheses
is employed in this work to minimize the probability of implant failure or maximize prosthesis …

Modeling dental implant insertion

A Dorogoy, D Rittel, K Shemtov-Yona… - Journal of the mechanical …, 2017‏ - Elsevier
The success of dental implantation is connected with the so-called implant primary stability,
a synonym for the implant anchoring inside the bone. The primary stability is related to the …

Nonlinear finite element analysis of three implant–abutment interface designs

CB Tang, SY Liu, GX Zhou, JH Yu, GD Zhang… - International journal of …, 2012‏ - nature.com
The objective of this study was to investigate the mechanical characteristics of implant–
abutment interface design in a dental implant system, using nonlinear finite element analysis …