Biomechanical behaviours of the bone–implant interface: a review
In recent decades, cementless implants have been widely used in clinical practice to replace
missing organs, to replace damaged or missing bone tissue or to restore joint functionality …
missing organs, to replace damaged or missing bone tissue or to restore joint functionality …
Biomechanical properties of artificial bones made by Sawbones: A review
R Zdero, P Brzozowski, EH Schemitsch - Medical Engineering & Physics, 2023 - Elsevier
Biomedical engineers and physicists frequently use human or animal bone for orthopaedic
biomechanics research because they are excellent approximations of living bone. But, there …
biomechanics research because they are excellent approximations of living bone. But, there …
Design and manufacture of customized dental implants by using reverse engineering and selective laser melting technology
J Chen, Z Zhang, X Chen, C Zhang, G Zhang… - The Journal of prosthetic …, 2014 - Elsevier
Statement of problem Recently a new therapeutic concept of patient-specific implant
dentistry has been advanced based on computer-aided design/computer-aided …
dentistry has been advanced based on computer-aided design/computer-aided …
Comparison of proximal humeral bone stresses between stemless, short stem, and standard stem length: a finite element analysis
N Razfar, JM Reeves, DG Langohr, R Willing… - Journal of shoulder and …, 2016 - Elsevier
Background The stem lengths of humeral components used in shoulder arthroplasty vary;
however, the literature on these devices is limited. This finite element study investigates the …
however, the literature on these devices is limited. This finite element study investigates the …
Investigating the impact of diameters and thread designs on the Biomechanics of short implants placed in D4 bone: a 3D finite element analysis
AR Alqahtani, SR Desai, JR Patel, NR Alqhtani… - BMC Oral Health, 2023 - Springer
Background Dental implants emerge as a dependable and efficacious alternative for
patients experiencing partial or complete tooth loss. The stability of these implants is …
patients experiencing partial or complete tooth loss. The stability of these implants is …
The influence of custom-milled framework design for an implant-supported full-arch fixed dental prosthesis: 3D-FEA sudy
The current study aimed to evaluate the mechanical behavior of two different maxillary
prosthetic rehabilitations according to the framework design using the Finite Element …
prosthetic rehabilitations according to the framework design using the Finite Element …
Intrinsic osteoinductivity of porous titanium scaffold for bone tissue engineering
M Tamaddon, S Samizadeh, L Wang… - International journal …, 2017 - Wiley Online Library
Large bone defects and nonunions are serious complications that are caused by extensive
trauma or tumour. As traditional therapies fail to repair these critical‐sized defects, tissue …
trauma or tumour. As traditional therapies fail to repair these critical‐sized defects, tissue …
Topological optimization in hip prosthesis design
M Fraldi, L Esposito, G Perrella, A Cutolo… - … and modeling in …, 2010 - Springer
With particular interest on total hip arthroplasty (THA), optimization of orthopedic prostheses
is employed in this work to minimize the probability of implant failure or maximize prosthesis …
is employed in this work to minimize the probability of implant failure or maximize prosthesis …
Modeling dental implant insertion
The success of dental implantation is connected with the so-called implant primary stability,
a synonym for the implant anchoring inside the bone. The primary stability is related to the …
a synonym for the implant anchoring inside the bone. The primary stability is related to the …
Friction coefficient and effective interference at the implant-bone interface
NB Damm, MM Morlock, NE Bishop - Journal of biomechanics, 2015 - Elsevier
Although the contact pressure increases during implantation of a wedge-shaped implant,
friction coefficients tend to be measured under constant contact pressure, as endorsed in …
friction coefficients tend to be measured under constant contact pressure, as endorsed in …