Turnitin
降AI改写
早检测系统
早降重系统
Turnitin-UK版
万方检测-期刊版
维普编辑部版
Grammarly检测
Paperpass检测
checkpass检测
PaperYY检测
Tribological characteristics of LM13 alloy based ilmenite-boron carbide reinforced hybrid composites for brake drum applications
Aluminium matrix hybrid composites reinforced with a combination of naturally occurring
ilmenite mineral particles (FeTiO 3) and synthetically processed boron carbide ceramic …
ilmenite mineral particles (FeTiO 3) and synthetically processed boron carbide ceramic …
[HTML][HTML] Wear assessment of a Ti–6Al–4V motion-preserving porous artificial-cervical-joint fabricated by SLM after surface carburization
W Yang, H Diao, H **n, W Chen, S Wang, L Xue… - Ceramics …, 2022 - Elsevier
Adjacent segment degenerative diseases are a major clinical concern for anterior cervical
corpectomy with fusion surgery. In this study, a hybrid motion-preserving cervical prosthesis …
corpectomy with fusion surgery. In this study, a hybrid motion-preserving cervical prosthesis …
[HTML][HTML] Effect of temperature on UHMWPE and VEXLPE friction and wear against CoCr in noncyclic tests
In prosthetic joints, frictional heating may cause protein denaturation in synovial fluid which
may affect its lubrication properties. In arthroplasty, conventional ultra-high molecular weight …
may affect its lubrication properties. In arthroplasty, conventional ultra-high molecular weight …
[HTML][HTML] VEXLPE friction studied with a multidirectional hip joint simulator using contact temperature control
V Saikko - Tribology International, 2023 - Elsevier
Frictional torque of VEXLPE and UHMWPE acetabular liners against CoCr and ZTA femoral
heads was measured with a multidirectional hip joint simulator for a wide range of …
heads was measured with a multidirectional hip joint simulator for a wide range of …
Coupling influence between environmental factors and synovial fluid components on tribological behavior of hip joint materials
J Cen, Q Chen, K Chen, X Zhang, H Feng, C Feng… - Tribology …, 2025 - Elsevier
Environmental factors greatly affect the tribological behavior of hip joint materials in synovial
fluid. In this paper, four groups of the synovial fluid with different concentrations of albumin …
fluid. In this paper, four groups of the synovial fluid with different concentrations of albumin …
Lubricant biochemistry affects polyethylene wear in knee simulator testing
Lubricant composition has been shown to influence knee simulator wear. In the present
study, three types of lubricants each having different biochemistries were used in knee …
study, three types of lubricants each having different biochemistries were used in knee …
Effect of synovial fluid temperature on wear resistance of different polymer acetabular materials
D Li, S Wang, H Lin, K Wang, Y Guo… - Journal of …, 2023 - journals.sagepub.com
In order to investigate the effect of frictional heat on the wear resistance characteristics of
polymeric acetabular materials, the tribological tests and wear numerical analysis of three …
polymeric acetabular materials, the tribological tests and wear numerical analysis of three …
[PDF][PDF] Tribological evolution of ultra-high molecular weight polyethylene and its composites for hip and knee replacement implants: A
In total joint replacement surgery, a damaged joint is replaced with a prosthetic joint made of
metal, ceramic, or plastic components (Affatato et al., 2012; Balagna, Spriano, & Faga …
metal, ceramic, or plastic components (Affatato et al., 2012; Balagna, Spriano, & Faga …
Modification of a simplified hip joint simulator into an ISO 14242-1 compliant design and a comparison of wear test results
The ISO 14242-1 standard for hip joint simulator wear testing specifies a set of test
conditions for the simulation of normal level walking in optimal conditions. Since some of the …
conditions for the simulation of normal level walking in optimal conditions. Since some of the …
Tribological behavior of ultra-high molecular weight polyethylene (UHMWPE) for acetabular replacement under frictional heat based on molecular dynamics
S Wang, K Wang, X Fang, D Li, H Lin… - Journal of Polymer …, 2023 - degruyter.com
Hip prostheses generate higher frictional heat than natural joints at the joint head-socket
interface during in vivo service, resulting in higher temperatures of the contact surfaces and …
interface during in vivo service, resulting in higher temperatures of the contact surfaces and …