Tractography methods and findings in brain tumors and traumatic brain injury

FC Yeh, A Irimia, DC de Almeida Bastos, AJ Golby - Neuroimage, 2021 - Elsevier
White matter fiber tracking using diffusion magnetic resonance imaging (dMRI) provides a
noninvasive approach to map brain connections, but improving anatomical accuracy has …

MR artifacts, safety, and quality control

J Zhuo, RP Gullapalli - Radiographics, 2006 - pubs.rsna.org
Artifacts in magnetic resonance (MR) imaging result from the complex interaction of
contemporary imager subsystems, including the main magnet, gradient coils, radiofrequency …

Characterization of and correction for eddy current artifacts in echo planar diffusion imaging

P Jezzard, AS Barnett… - Magnetic resonance in …, 1998 - Wiley Online Library
Magnetic resonance diffusion imaging is potentially an important tool for the noninvasive
characterization of normal and pathological tissue. The technique, however, is prone to a …

Self‐navigated spiral fMRI: interleaved versus single‐shot

GH Glover, S Lai - Magnetic resonance in medicine, 1998 - Wiley Online Library
This study compares the measured activation volumes in motor cortex as well as the
fluctuation noise and off‐resonance characteristics for 1‐, 2‐, and 4‐shot spiral gradient …

Reducing sensitivity losses due to respiration and motion in accelerated echo planar imaging by reordering the autocalibration data acquisition

JR Polimeni, H Bhat, T Witzel, T Benner… - Magnetic resonance …, 2016 - Wiley Online Library
Purpose To reduce the sensitivity of echo‐planar imaging (EPI) auto‐calibration signal
(ACS) data to patient respiration and motion to improve the image quality and temporal …

Ghost artifact reduction for echo planar imaging using image phase correction

MH Buonocore, L Gao - Magnetic resonance in medicine, 1997 - Wiley Online Library
An algorithm is described for reducing ghost artifacts in echo planar imaging (EPI) using
phase corrections derived from images reconstructed using only even or odd k‐space lines …

High‐resolution human diffusion tensor imaging using 2‐D navigated multishot SENSE EPI at 7 T

HK Jeong, JC Gore… - Magnetic resonance in …, 2013 - Wiley Online Library
The combination of parallel imaging with partial Fourier acquisition has greatly improved the
performance of diffusion‐weighted single‐shot EPI and is the preferred method for …

Evaluation of the early response in fMRI in individual subjects using short stimulus duration

X Hu, TH Le, K Uǧurbil - Magnetic resonance in medicine, 1997 - Wiley Online Library
Optical imaging studies have provided evidence of an initial increase in deoxyhemoglobin
following the onset of neuronal stimulation/activation and demonstrated that this initial …

Rapid brain MRI acquisition techniques at ultra‐high fields

K Setsompop, DA Feinberg, JR Polimeni - NMR in Biomedicine, 2016 - Wiley Online Library
Ultra‐high‐field MRI provides large increases in signal‐to‐noise ratio (SNR) as well as
enhancement of several contrast mechanisms in both structural and functional imaging …

Clinical multishot DW‐EPI through parallel imaging with considerations of susceptibility, motion, and noise

S Skare, RD Newbould, DB Clayton… - … in Medicine: An …, 2007 - Wiley Online Library
Geometric distortions and poor image resolution are well known shortcomings of single‐shot
echo‐planar imaging (ss‐EPI). Yet, due to the motion immunity of ss‐EPI, it remains the most …